WinterWarm Fireplace Insert or System
2000941
Section I Operation
Your WinterWarm’s Controls 
and What They Do
Three controls regulate the performance of your Win-
terWarm:  A primary air control supplies oxygen for the 
fire, a damper directs air flow within the fireplace, and 
a variable-speed fan control, or rheostat, regulates the 
warm air flow into the room. (Fig. 2)
Primary Air Control
A single air control regulates the amount of heat the fire 
will produce and how long it will burn.
The primary air control is located above the upper left 
corner of the door.  It is the top-most of the two brass-
capped controls located there (the brass knob on the 
bottom regulates the fan), and is the primary source of 
air for starting, maintaining, and reviving the fire. 
Generally, more air entering the stove makes the fire 
burn hotter and faster, while less air prolongs the burn.
The WinterWarm’s air supply is open to the maximum 
when the control lever is moved to the left, and closed 
when moved to the far right. It may be set anywhere 
between the two extremes, however, depending on the 
amount of heat desired.
To complement the manual setting of the air control, the 
WinterWarm has an internal automatic thermostat that 
ensures an even delivery of heat at the manual setting 
you select.
The Damper
The damper directs air flow within the fireplace. 
The damper is operated by moving the lever located 
above the upper right corner of the door.  It has two 
positions:  Open, to start or revive the fire (Fig. 3); and 
closed (Fig. 4), for normal operation. The damper is 
open when the lever is to the far left, and closed when 
to the far right. There are no intermediate settings for 
damper position. 
When the damper is closed, the front door automatically 
locks to prevent the door being inadvertently opened 
when the fireplace is in its catalytic mode. This could 
cause smoke to spill into the room. 
To open the damper, lift up on the lever and move it 
to the far left. The lock will disengage, allowing you to 
open the front door.   
To close the damper, move the lever to the right, 
continuing past the resistance to lock the damper in 
position.  (The door handle must be positioned vertically 
before the lock mechanism will engage.)  
FP1070
Winter Warm Controls
3/01
Primary Air Control (Top Lever)
Fan Speed Control 
(Rheostat) (Bottom 
Lever)
Damper Control
Door Handle
Optional Outside 
Air Control
FP1070
Fig. 2  All WinterWarm controls are located conveniently on 
the front.
FP1072
WW 
damper closed
3/27/01   djt
Damper Closed
Catalytic 
Combustor
FP1072
Fig. 4  Damper is closed: Smoke is channelled through the 
catalytic combustor where much of it can be burned.
FP1071
WW 
damper open
3/27/01   djt
Damper 
Open
FP1071
Fig. 3  The damper is open; Smoke is vented directly to the 
chimney.