INSTALLATION 
 
PRODUCT FEATURES AND CONTROLS 
 
PAGE 12 
POSITIVE FLUE CONNECTION FOR MASONRY 
FIREPLACE (continued)
 
 
A preferable installation is the positive flue connection 
(a positive seal between the flue extension and the 
chimney). This can be achieved by using a filler plate. 
A filler plate can be made by making a cardboard pat-
tern to fit the fireplace throat. Lay the pattern on 22 
gage steel, add 2 inches (51 mm) to each side, and 
cut. Snip corners and bend front lip up and sides and 
back down. Cut an opening for the flue. Attach filler 
plate with masonry screws. 
 
Filler Plate 
 
 
 
The starter pipe extends through the filler plate, past 
the damper and into the existing chimney system. 
Small air leaks should be sealed with high temp fiber-
glass or ceramic insulation. 
 
 
BLOWER SYSTEM 
The 500-CFM room air circulation blower system comes 
equipped with a variable speed control (rheostat). The blower 
system can be operated manually or set to operated automati-
cally (so the blowers will turn on when the insert is hot and turn off 
when the insert is cool). See Care and Operation Section – 
Blower System on page 16. 
 
Blower System Controls 
Located on right side of door at bottom of panel. 
 
 
PRIMARY AIR CONTROL 
The primary combustion air delivery is controlled by the pri-
mary air control draft module (The control handle is located 
below the fuel door in the center). The heat output can be con-
trolled by pushing the handle in for a higher burn rate or pulling 
it out for a lower burn rate. The fuel, the amount of heat and 
burn times desired, the type of installation are all variables that 
will affect the control setting. The same control settings in a 
variety of installations will produce different results. You will 
need to try different settings so you can learn how much heat to 
expect and how long the fire will burn
 
 
START-UP AIR CONTROL 
The start-up air control provides additional air delivery to assist in 
establishing a draft in a cold flue system (The control handle is 
located below the fuel door on the left). From a cold start, ap-
proximately 10 minutes in the open position is all that is required 
to achieve a stable burn.