NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Table 
l
ower
 f
ront
 2” f
iller
 p
anel
The FireStar™ insert comes with a 2” panel to fill the space be-
tween the insert bottom and the hearth extension. If the hearth
elevations necessitate, the insert may be installed directly on the
hearth without the leveling bolts or filler panel. To install the panel,
insert the four tabs on the top of the panel into the corresponding
slots in the insert bottom. Open the insert side doors, remove the
two socket head screws from the hardware bag and install them
(using a 5/32” hex wrench) through the insert bottom into the filler
panel. A tall adjustable filler panel is also available.
g
as
 l
ine
 i
nstallation
After leveling, position the insert in the fireplace, holding it about
six inches out from its final location.
Caution: Specific Hearth Requirements apply (see Clearances 
and Specifications). The Firestar gas insert must be connected 
to  the  gas  line  in  accordance  with  local  codes  and  /  or  the 
National Fuel Gas Code,  Z.1-latest edition, also known as 
NFPA 54. Included in the manual package is an 8" gas nipple.  
Locate the threaded gas inlet on the lower left of the insert.  
Thread the 8" gas nipple into the inlet with a teflon sealer or 
equivalent.  Attach the gas supply line to this hard pipe.  The 
hard pipe can receive a /8” inch female iron pipe coupling, or a 
shut off valve. After connecting the gas line, all joints in the line 
and connections at the valve should be checked for leaks.
g
as
 p
ressure
 r
equirements
A  MAJOR  CAUSE  OF  OPERATING  PROBLEMS  WITH  GAS 
APPLIANCES IS IMPROPER GAS PRESSURE!
The  most  important  item  to  check  during  the  initial 
installation and the first thing to check when operating 
problems occur is gas pressure! This appliance will not 
function  properly  unless  the  required  gas  pressure  is 
supplied. See Table 1 for gas pressure requirements. 
Two pressure taps are provided on the insert's valve to check
gas pressures. The taps are located below the on/off/pilot knob
(see Figure 14). The left tap is the inlet (supply) pressure side.
To check inlet pressure (with the insert burning), insert a small
phillips  screwdriver  into  the  tap  and  turn  a  half  turn  counter-
clockwise.  Cover  the  tap  with  the  line  from  a  manometer  and
check the pressure. Close tap gently but securely after completing
the check. The manifold (outlet) tap is to the right of the inlet tap.
To check manifold pressure (with the insert burning at the high
burn setting) insert a small
phillips  screwdriver  into
the tap and turn a half turn
counter-clockwise.  Cover
the tap with the line from
the manometer and check
the  pressure.  Again  close
the tap gently but securely
after completing the check.
Check the taps for gas leaks
with a gas leak test solution
(retighten if necessary).
g
as
 s
upply
 l
ine
 s
izing
The proper gas line diameter must be selected to run from the
supply regulator to the insert. Refer to the Table 2 for proper gas
pipe diameters.
NOTE:  Some areas allow copper tubing - check with local approval
agencies and codes.
COPPER  TUBING  NOT  ALLOWED  IN  MASSACHUSETTS  IN 
NATURAL GAS INSTALLATIONS, NEVER USE GALVANIZED OR 
PLASTIC PIPES.
Fuel                     
Type
Inlet Pressure
Manifold Pressure
Desired Minimum Maximum
On Hi 
Fire
On Lo 
Fire
Natural
Gas
7" WC
5" WC
10.5" WC
.5" WC
1.7" WC
LP Gas 11" WC 10.5" WC
1" WC
10.0" WC 5.4” WC
Table 1
12
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
1
/
2
"
(1.3 cm)
7
/
8
"
(2.3 cm)
3
/
4
"
(2.0 cm)
3
/
4
"
(2.0 cm)
150-200
3
/
4
"
(2.0 cm)
100-150
1
/
2
"
(1.3 cm)
7
/
8
"
(2.3 cm)
3
/
4
"
(2.0 cm)
1
/
2
"
(1.3 cm)
3
/
4
"
(2.0 cm)
1
/
2
"
(1.3 cm)
1
/
2
"
(1.3 cm)
40-100
1
/
2
"
(1.3 cm)
5
/
8
"
(1.6 cm)
1
/
2
"
(1.3 cm)
10-40
3
/
8
"
(1.0 cm)
1
/
2
"
(1.3 cm)
3
/
8
"
(1.0 cm)
1
/
2
"
(1.3 cm)
0-10
Natural Gas
Natural Gas
L.P.
L.P.
Pipe Length
(Feet from Supply 
Regulator)
(Do Not Use Copper in Massachusetts 
with Natural Gas)
Tubing, Type L Outside Diam-
eter (Copper)
Schedule 40 Pipe
Inside Diameter
(Black Pipe)
1
/
2
"
(1.3 cm)
Gas Line Installation
After leveling, position the insert in the fireplace --- holding it 
about six inches out from its final location.
Caution: Specific Hearth Requirements apply (see Clearances 
and Specifications). The 
Designer™
 must be connected to the 
gas line in accordance with local codes and / or the National Fuel 
Gas Code--- 
Z223.1-latest edition, also known as NFPA 54 
(In Canada, the current CAN/CSA  B149.1 installation code)
.
Included in the manual package is a 8" gas nipple.  Locate the 
threaded gas inlet on the lower left of the insert.  Thread the 
8" gas nipple into the inlet with a teflon sealer or equiv.  Attach 
the gas supply line to this hard pipe.  The hard pipe can receive 
a 3/8” inch female iron pipe coupling, or a shut off valve. After 
connecting the gas line, all joints in the line and connections 
at the valve should be checked for leaks.
G
as
s
upply
l
ine
s
izinG
The proper gas line diameter must be selected to run from the 
supply regulator to the stove.  Refer to the following table for 
proper gas pipe diameters.
NOTE:  Some areas allow copper tubing - check with local approval 
agencies and codes.
COPPER  TUBING  NOT  ALLOWED  IN  MASSACHUSETTS  IN 
NATURAL GAS INSTALLATIONS, NEVER USE GALVANIZED OR 
PLASTIC PIPES.
Figure 14
If the pressure is not sufficient, make sure the gas supply line
is large enough, the supply regulator is properly adjusted, and
the total gas load for the residence does not exceed the amount
supplied.
The  appliance  and  its  individual  shut  off  valve  must  be 
disconnected from the gas supply piping system during any 
pressure testing of that system at test pressures in excess of 
1/ psig.
The  appliance  must  be  isolated  from  the  gas  supply  piping 
system by closing its individual manual shut-off valve during 
any pressure testing of the gas supply piping system at test 
pressures equal to or less than 1/ psig.  Check with your gas 
supplier or plumber.
Inlet
Pressure
Tap
Inlet Elbow
Off/On/Pilot
Manifold 
Pressure Tap
Flame Height
Adjustment
Outlet
Orifice