8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Installation
i
nsert
 v
enting
Refer to Figure 6 which shows a typical installation of this ap-
pliance into an existing solid-fuel fireplace.
WARNING: This appliance is equipped with a safety control sys-
tem designed to protect against improper venting of combustion
products. Operation of this heater when not connected to a prop-
erly installed and maintained venting system or tampering with
the blocked vent shut-off system can result in carbon monoxide
(CO) poisoning and possible death.
Insert must be vented to the outside in accordance with the current
edition of the National Fuel Gas Code ANSI-
Z223.1-latest edition,
also known as NFPA 54
. The insert must not be connected to a
chimney flue serving a separate solid fuel burning appliance.
This gas insert requires a 4” diameter B-vent or listed flex alu-
minum  or  stainless  chimney  liner  extending  the  entire  length
of  the  chimney  to  ensure  proper  operation.    The  vent  should
terminate with a chimney cap or rain cap. Chimney should be
sealed around cap to prevent air and rain from entering chimney.
Adhere to vent manufacturer's instructions for installation and
vent termination.
A minimum flue height of 1 feet is recommended. 
The insert must be installed so the draft hood is in the same 
atmospheric pressure zone as the combustion air inlet to the 
appliance. 
f
lue
 C
ollar
 C
onneCtion
This  insert  has  a  detachable  flue
collar to ease installation. To detach
flue collar lift removable vent (trivet)
from top of insert, unscrew draft tube
retaining  screw  (see  Figure  5)  and
slide draft tube and flue collar to the
rear. Attach flue collar (with 3 sheet
metal screws or a B-vent connector)
to  vent  pipe  previously  installed  in
chimney. As the insert is pushed into
fireplace guide draft tube and flue col-
lar into guide brackets until draft tube
retaining screw can be reinstalled in
its original hole.
Chimney Cap
Storm Collar
Chimney  -  Use  With 
B-vent  Chimney  Or 
Single  Wall  Gas  Vent 
Flex  Chimney  Liner 
Listed  To  UL  1777  Or 
ULC S65.  
        
WARNING
Do not substitute the heat-rated flex liner (UL1777 or ULC 
S65) for the exhaust with any other type liner or a fire 
may result causing property damage, personal injury or 
loss of life.
VENT KITS
Cat. #
Model
Description
H0906
VKBVI5
BVI, 4" Dia. x 5’ Length
H0907
VKBVI5
BVI, 4" Dia.  x 5’ Length
Figure 7
Figure 6
Figure 5
Draft Tube
Retaining
Screw
The following vent liner kits are available from Lennox Hearth 
Products (see Figure 7 and table below).