Lopi Freedom Bay Fireplace Insert 사용자 설명서

다운로드
페이지 32
10
Installation 
(for qualified installers only)
© Travis Industries
100-01163
4041129
Drafting Performance
This appliance relies upon natural draft to operate.  External forces, such as wind, barometric pressure,
topography, or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.),
may adversely affect draft.  Travis Industries can not be responsible for external forces leading to less
than optimal performance.
Leveling Bolt Installation
Two leveling bolts are included to level the insert if the fireplace has a stepped-up hearth.  To install, raise
the rear of the insert up and insert the leveling bolts into the holes in the rear corners of the insert.  Adjust
the bolts until they extend the same height as the hearth steps up.  After the insert is installed, fine-tune
the leveling bolts to level the insert (see Figure 4).
AAA
AAA
AAA
AAA
AAA
AAA
This distance is the 
hearth step-up.  The 
leveling bolts should 
stick out this far from the 
base of the insert.
Fireplace
Hearth
The leveling bolts go 
into the holes at the 
rear corners of the 
insert.
Figure 4
Blower Installation
The included blower is fragile and should be installed last (see the directions below).
AA
AA
AA
A
A
A
Remove the two 
screws underneath the 
ashlip with a 3/8" 
nutdriver.  Align the 
blower under the 
ashlip and replace the 
two screws to secure.
AAAA
AAAA
AAAA
AAAA
AAAAA
AAAAA
AAAAA