Regency P40-NG1 사용자 설명서

다운로드
페이지 56
Regency
®
 P40-1 Direct Vent Gas Fireplace
40
OPERA
TION
OPERATING INSTRUCTIONS
OPERATING 
INSTRUCTIONS
1)  Read and understand these instructions 
before operating this appliance.
2)  Check to see that all wiring is correct and 
enclosed to prevent possible shock.
3)  Check to ensure there are no gas leaks.
4)  Make sure the glass in the door frame is 
properly positioned. Never operate the 
appliance with the glass removed.
5)  Verify that the venting and cap are 
unobstructed.
6)  Ensure that the brick panels are installed.
7)  Verify log placement. If the pilot cannot be 
seen when lighting the unit, the logs have 
been incorrectly positioned.
8)  The unit should never be turned off, and on 
again without a minimum of a 60 second 
wait.
IMPORTANT Gas on/off knob cannot be 
turned from "PILOT" to "OFF" unless it is 
partially depressed.
Ensure that the 3 way switch on the manual 
control panel is in the "Remote" position.
1)  Push in gas control knob slightly and turn 
clockwise to “OFF”. Knob cannot be turned 
from “PILOT” to “OFF” unless knob is pushed 
in slightly.  Do not force.
2) Wait fi ve (5) minutes  to clear out any gas. 
3)  Turn knob  on gas control counterclockwise        
to “PILOT”.
4)  Push in control knob all the way and hold  in 
until the pilot lights up. Continue to hold the 
control knob in for about 20 seconds after 
the pilot is lit. Release knob and it will pop 
back up. Pilot should remain lit. If it goes out, 
repeat steps 1) to 4).  If knob does not pop 
up when released, stop and immediately 
call your service technician or gas supplier. 
If the pilot will not stay lit after several tries, 
turn the gas control knob to “OFF” and call 
your service technician or gas supplier.
5)  Turn gas control knob counterclock-wise to 
“ON”.
6)  Turn the unit on. 
 
NOTE: If using the remote control refer to 
the FireWizard manual for instructions.
SHUTDOWN 
PROCEDURE
1)  Press the ON/OFF switch once.
2)  The LED will fl ash.
3)  Turn the main gas control clockwise to the 
"OFF" position to turn off the pilot.
4)  Turn off all electric power to appliance if 
service is to be performed.
Only when the pilot holds, without pressure 
being applied to the control knob, reapply the 
tension springs to the door. The unit must 
not
 be operated with the tension springs 
unattached. 
IMPORTANT
To ignite or reignite the pilot, 
you must fi rst release the 
tension springs below the door. 
LIGHTING 
PROCEDURE
3-way Switch
Manual Control Panel
MATCHING REMOTE 
HANDSET & CONTROL 
BOX ID CODE
The Remote Control Handset has a set of 
unique ID codes that is pre-programmed into its 
memory. This set of ID codes helps to differenti-
ate one Remote Control Handset from another 
so that only the control box with a matching ID 
code will respond to the appropriate Remote 
Control Handset.
To ensure the remote control is matched to 
the receiver correctly, please follow the steps 
below: 
1.  Ensure that the Remote Control and the 
3-way switch located at the appliance are 
both in the OFF position.
2.  Ensure that the pilot is lit and the pilot 
control knob is in the ON position on the 
appliance.
3.  Install the 2 x AAA alkaline batteries into the 
Remote Control.
4.  Unplug and re-plug the power cord. The 
power cord is located on the left hand side 
of the appliance and will be plugged into the 
receptacle.
5.  Switch the 3-way switch located on the ap-
pliance to the REMOTE position.
6.  Press and hold the PROG and FAN buttons 
simultaneously for up to 20 seconds. During 
this time, the remote will display LC while it 
is transmitting codes to the receiver. Once 
it is successfully transmitted, one will hear 
the solenoid click and the burners will come 
on. If is does not work the fi rst time, repeat 
steps 1 - 6. 
7.  Release both the PROG and FAN buttons. 
The remote will revert back to normal, but 
the burner will still be on.
8.  Press the ON/OFF button on the remote 
control 2 times to turn the burner off.
9.  The remote control is now programmed to 
the receiver and the appliance can now be 
operated with it.
The control box will only learn the Remote ID 
codes during the fi rst 30 seconds after power 
is applied and will ignore this special command 
from the Remote after the fi rst 30 seconds. 
NOTE: This must only be performed by a quali-
fi ed installer.