U32-4 FPI Direct Vent Gas Insert
IMPORTANT MESSAGE  
SAVE THESE 
INSTRUCTIONS
The FPI Gas Insert must be installed in 
 
accordance with these instructions. Carefully 
read all the instructions in this manual fi rst. 
Consult the building authority having jurisdiction 
to determine the need for a permit prior to starting 
the installation.
NOTE:  Failure to follow the instructions could 
cause a malfunction of the heater which could 
result in death, serious bodily injury, and/or 
property damage.  Failure to follow these 
instructions may also void your fi re insurance 
and/or warranty. 
FOR YOUR SAFETY
This appliance requires air for proper combustion.  
Always provide adequate combustion and 
ventilation air.  Follow instructions and 
information in CAN/CGA B149 (in Canada) or 
the National Fuel Gas Code ANSI Z223.1 (in the 
USA), regarding requirements for combustion 
and ventilation air.
SPECIFICATIONS
At pressures over 1/2 psig, the pipe to the unit 
must be disconnected.
Gas Input Capacity:  
 Natural 
Gas 
30,000 
Btu/h
 Propane  30,000 
 
Btu/h
Min. Input
 
Natural Gas 
15,300    Btu/h
 Propane  15,000 
 
Btu/h
Fuels:  Approved for use with both natural gas, 
and propane. Approved as is for use at 0' to 
4,500' (0-1370m).
Electrical:  120V   A.C. system.
Circulation Fan:  Variable speed, 110 CFM.
Log Set:  Ceramic fi bre, 7 per set.
Vent System:   3" co-linear aluminum fl ex.
The effi ciency rating of the appliance is a 
product thermal effi ciency rating determined 
under continuous operating conditions and 
was determined independent of any installed 
system.
INSTALLATION
GAS PRESSURE 
TESTING
The appliance must be isolated from the gas 
supply piping system by closing its individual 
manual shut off valve during any pressure 
testing of the gas supply piping system at test 
pressures equal to or less than
1/2 psig. (3.45 kPa).
INSTALLATION INTO A 
SOLID FUEL BURNING 
FIREPLACE OR 
FACTORY BUILT 
FIREPLACE
The U32-4 Gas Inserts have been tested and 
approved to be vented into any masonry fi replace 
or  approved solid fuel burning factory built 
fi replace that will allow the insert to physically 
fi t into the fi rebox. Refer to "Minimum  Fireplace 
Dimensions" section for minimum fi replace 
clearances.
If the factory built fi replace* height is too low for 
your Insert, you may remove the smoke baffl e 
plate, damper, refractory (fi rebricks), glass 
doors, screen rails, screen mesh and log grates 
from the factory built fi replace as long as these 
items are saved and are reinstalled in the event 
that the Insert is removed. 
Smoke shelves, shields and baffl es may be 
removed if attached by mechanical fasteners. 
If any part is removed it must not weaken the 
structural integrity of the factory built fi replace.
NOTE: Any alterations made to the listed solid 
fuel burning factory built fi replace may void the 
listing of the fi replace.
*Check with your local inspector before 
commencing with this installation.
BEFORE YOU START
Safe installation and operation of this appliance 
requires common sense, however,  we are 
required by the Canadian Safety Standards 
and ANSI Standards to make you aware of 
the following:
General Safety Information
1)  The appliance installation must conform 
with local codes or in the absence of local 
codes, with CAN/CGA B149 (in Canada) or 
the National Fuel Gas Code ANSI Z223.1 in 
the U.S.A. This appliance should be installed 
by a qualifi ed gas fi tter technician only.
2)  Installation and repair should be done 
by a qualifi ed service person.  
3)  The  appliance should be inspected before 
use and at least annually by a professional 
service person. More frequent cleaning 
may be required due to excessive lint from 
carpeting, bedding material, animal hair, etc.  
It is imperative that control compartments, 
burners and circulating air passageways of 
the appliance be kept clean. 
4)  See general construction and assembly 
instructions. This appliance may only be 
installed in a vented, noncombustible 
fi replace.
5)  This appliance is Listed for bedroom 
 
installations when used with a Listed Millivolt 
Thermostat. Some areas may have further 
requirements, check local codes before 
installation.
6)  Always connect this insert to a vent system 
venting to the outside of the building 
envelope. Never vent  to another room or 
inside a building.  Make sure that the vent 
is properly sized and is of adequate height 
to provide the proper draft.  
7)  Inspect the venting system annually for 
blockage and any signs of deterioration.   
8)  Any glass removed for servicing must be 
replaced prior to operating the appliance.  
9)  To prevent  injury, do not allow anyone who 
is unfamiliar with the operation to use the 
fi replace.  
10) Due to high temperatures, the appliance 
should be located out of high traffi c areas 
and away from furniture and draperies. 
Children and adults should be alerted to 
the hazards of high surface temperatures, 
especially the fi replace glass and gold 
trims, and should stay away to avoid burns 
or clothing ignition. Young children should 
be carefully  supervised when they are in 
the same room as the appliance. Clothing 
or other fl ammable material should not be 
placed on or near the appliance.
Emissions from burning  wood or gas could 
contain chemicals known to the State of 
California to  cause cancer, birth defects or 
other reproductive harm.
Installer must mechanically attach the supplied 
label to the inside of the fi rebox of the fi replace 
into which the gas fi replace insert is installed.
"WARNING: This fi replace has been converted 
for use with a gas fi replace insert only and 
cannot be used for burning wood or solid fuels 
unless all original parts have been replaced, 
and the fi replace re-approved by the authority 
having jurisdiction."