Quadra-Fire CB1200I 사용자 설명서

다운로드
페이지 52
February 3, 2010
7014-188B
Page  39
CB1200-I Pellet Insert
G.  Baffle Removal
  a.  Be sure the appliance is allowed to cool, has been 
unplugged and the exhaust blower is off.
  b.  Open glass door.
  c.  Grasp the bottom of the baffles and pull up to dis-
lodge from hook attachment.
  d.  Use a standard screw driver to unlatch the covers 
beneath the baffles of each side.
  e.  Re-install in reverse order.
F.  Igniter Replacement
  a.  Be  sure  the  appliance  is  allowed  to  cool,  has  been 
unplugged and the exhaust blower is off.  Remove the 
ash pan.
  b.  The wire leads to the igniter are connected to the wire 
harness with 1/4 inch male / female spade connectors.  
These  wires  will  pull  forward  approximately  4  to  5 
inches  (102mm  to  127mm).    Disconnect  the  spade 
connections and remove the igniter from the chamber.  
Loosen the thumb screw and slide igniter out.
  c.  Install  new  igniter  into  the  chamber  and  tighten  the 
thumb screw.  Re-connect the wires to the 2 leads with 
the spade connectors.
  d.  Push excess wire leads  to take-up the 4 to 5 inches 
(102mm to 107mm) previously pulled out.  This will 
keep the wires out of the way of the ash pan.  Double 
check that the igniter wires are clear of any movement, 
i.e. ash pan, firepot cleaning rod, etc.
  f.  Re-install the ash pan and re-connect the power.
Figure 39.1
Igniter
Igniter Bracket
Thumb Screw