CB1200-I Pellet Insert
NOTE:
  Illustrations reflect typical installations and 
are FOR DESIGN PURPOSES ONLY.
  Illustrations/diagrams are not drawn to 
scale.
  Actual installation may vary due to 
individual design preference.
B. Clearance To Combustibles, UL and ULC
12 in. 
(305mm)
Rear Shroud 
6 in. 
(152mm)
Shown with Hopper Extended 
Optional Outside 
Air 
Combustible 
Mantel 
INSTALLED AS A BUILT-IN UNIT
Shown with Rear Vent and Optional Outside Air
Figure 9.1
Figure 9.2
AS A BUILT-IN
B
D
C
E
B
C
A
0  INCH (0mm) CLEARANCE TO ExPOSED SECTION AND FACE TRIM
Rear Shroud Kit is Required for Built-In Installation
A
Top of Shroud
Top Vent
3.0 
76
Rear Vent
0
B
Sides of Inside Shroud
Top or Rear Vent
0
C
Back of Inside Shroud
Top Vent
2.5 
64
Rear Vent
0
D
Vent Pipe to Combustible
Top or Rear Vent
3.0 
76
Fire Risk.
WARNING
Failure to comply may cause house fire.
Comply with all minimum clear-
ances to combustibles as specified.
NOTICE:
Please note that while the minimum clear-
ance  for  the  termination  cap  is  6  inches 
(152mm)  there  is  the  possibly  of  soot 
buildup around the termination area.  If this 
occurs we suggest to move the termination 
further away from the house to prevent it.