The chart will help you in determing proper vent-
ing  size  according  to  the  equivalent  feet  of  pipe 
calcuated above and the altitude above sea level 
of this installation.  Figure 14.2.
Locate  the  calculated  equivalent  feet  of  pipe  on 
the  vertical  left  side  of  the  chart.    Move  to  the 
right horizontally on the chart until you reach your 
altitude above sea level.
If you fall below the diagonal line, 3 or 4 inch (76 
to 102mm) pipe may be used.  If it is anywhere 
above the diagonal line, a 4 inch (102mm) diameter 
pipe is required.  
The chart reveals that a 90° elbow is 5 times as 
restrictive to the fl ow of exhaust gases under posi-
tive  pressure  as  1  foot  of  horizontal  pipe,  and  a 
foot of horizontal pipe is twice as restrictive as a 
foot of vertical pipe.
D.  Pipe Selection Chart
The  table  below  can  help  you  calculate  the  equivalent  feet 
of pipe which is a method used to determine pellet vent size.  
Figure 14.1.
C.  Equivalent Feet of Pipe
2 ft.
2 ft.
3 ft.
2 ft.
Example of 3 Elbow-Rear Vent Termination Calculation
Figure 14.1
Pellet Venting 
Component
# of 
Elbows
Feet of 
Pipe
Multiplied 
By
Equivalent 
Feet
Components
Equivalent Feet
90
o
 Elbow or Tee
3
X
5
15
45
o
 Elbow
X
3
Horizontal Pipe
7
X
1
7
Vertical Pipe
2
X
0.5
1
Total Equivalent Feet
23
Note:  This is a generic example and is not 
intended to represent any specifi c fuel type.
Figure 14.2
3 in. or 4 in. (76mm or 102mm) Diameter  Pipe 
Equivalent Pipe 
Length In Feet
ALTITUDE IN THOUSANDS OF FEET 
20 
30 
1        2       3       4       5       6        7       8        9     10
4 in. (102mm) Diameter Pipe Only 
10 
Example 1
Example 2
Example 1:  If the equivalent length of pipe is 23 feet with altitude of 
8,000  feet  you  must  use  4  inch  (102mm)  diameter  type  “L”  or  “PL” 
vent.
Example 2:  If the equivalent length of pipe is 12 feet with altitude of 
6,000 feet you may use 3 or 4 inch (76 to 102mm) diameter type “L” 
or “PL” vent