Step 8.  Install the new pilot injector supplied with this conversion kit. Simply screw the new injector 
inside the pilot hood and reinstall the hood by placing the hood on the assembly, line up the 
key way, and snap into place.
Step 9.  Remove the main burner orifice with a 1⁄2 inch deep socket.
Step 10. Install the new orifice supplied. Be sure to put a bead of pipe-thread sealant or approved Teflon 
tape on the orifice before installing into the burner assembly. 
Step 11. Re-install burner tray, log set and door. Pay special attention when installing the burner that 
the venturi adjustment rod is properly installed into the venturi adjustment piece welded to the 
burner venturi tube. Also refer to S
ECONDARY
 I
NSTALLATION
 - I
NSTALLING
 L
OG
 S
ET
 
AND
 E
MBERS
.
Step 12. Open the shut-off valve at the gas line to the unit.
Step 13. Use a small brush to apply a warm soapy water solution to all gas connections (use a half 
dish soap and half warm water). If a gas leak is present, bubbling will occur. Gas leaks can 
be repaired by using an approved pipe thread sealant or approved Teflon tape. NEVER USE A 
NAKED FLAME WHEN TESTING FOR LEAKS.
Step 14. Re-light the fireplace to ensure proper operation and proper flame appearance, refer to Figure 
55.
Step 15. MAKE SURE that the sticker provided by S.I.T. is installed, to signify that the valve has been 
converted to a different fuel type.  Also, make sure that the rating plate has a conversion label 
to show this unit has been converted to a different fuel type.
A VISUAL CHECK OF THE REGULATOR KNOB IS NECESSARY TO DETERMINE WHETHER OR NOT THE 
REGULATOR IS THE CORRECT PART. A 50% TURN DOWN REGULATOR WILL HAVE ONLY ONE CORNER 
ON THE KNOB
Conversion Kit should contain the following:
(1) 50% turn down HI/LO regulator with three (3) T-20 Torx screws
(1) Pilot injector
Conversion instructions
Labels to show conversion
11
Table 1: Orifice Information.
Natural Gas
Propane
Pilot Orifice
.62 mm
.35 mm
Burner Orifice Top
#39 DMS
#53 DMS
Venturi Setting
1
/
16
” min.
3
/
16
” min.