Vermont Casting 2463 사용자 설명서

다운로드
페이지 32
12
Dutchwest
7001219
   
 Stove Installed 
Stove in 
 Stove Installed 
Stove in
   
 Parallel to Wall 
Corner 
 Paralle to Wall 
Corner
   
Side 
Rear 
Corners 
Side 
Rear 
Corners
  No heat shields 
(A) 22” 
(B) 24” 
(C) 18” 
(D) 12” 
(E) 14” 
(F) 10”
   
(559 mm) 
(610 mm) 
(457 mm) 
(305 mm) 
(356 mm) 
(254 mm)
  Rear exit, rear h.s. 
(G) 22” 
(H) 14” 
n/a 
(I) 12” 
(J) 12” 
n/a
   
(559 mm) 
(356 mm) 
 
(305 mm) 
(305 mm)
  Top exit
1
, rear h.s. 
(K) 22” 
(L) 24” 
(M) 18” 
(N) 12” 
(O) 14” 
(P) 10”  
  single-wall connector 
(559 mm) 
(610 mm) 
(457 mm) 
(305 mm) 
(356 mm) 
(254 mm) 
  No connector h.s.
  Top exit
1,2
, rear h.s. 
(K) 22” 
(L) 14” 
(M) 15” 
(N) 12”  
(O) 12” 
(P) 8”   
  single-wall connector 
(559 mm) 
(356 mm) 
(381 mm) 
(305 mm) 
(305 mm) 
(203 mm) 
  with connector h.s.
  Top exit
1
, rear h.s. 
(K) 22” 
(L) 15”  
(M) 19” 
(N) 12” 
(O) 11” 
(P) 8”   
  double-wall connector 
(559 mm) 
(381 mm) 
(483 mm) 
(305 mm) 
(279 mm) 
(203 mm)
 
  Single-wall connector 
 
19” 
 
 
9” 
 
 
  no connector h.s. 
 
(483 mm) 
 
 
(229 mm)
  Single-wall
2
 connector 
 
9” 
 
 
7” 
 
 
  with connector h.s. 
 
(229 mm) 
 
 
(178 mm)
  Double-wall connector 
 
14” 
 
 
6” 
 
 
   
 
(356 mm) 
 
 
(152 mm)
   
 
All Installation 
 
 
48” (1219 mm)
1.  Shielding for a top exit stove must include a shield insert to protect the area behind the flue collar.
2.  Chimney connector heat shields must extend exactly 24” (610 mm) above the flue collar of the stove.
3.  All installations venting straight up to a factory built chimney require a 24” (610 mm) diameter or square ceiling heat shield. The 
ceiling heat shield should be 24 gauge sheet metal or equivalent mounted on 1” (25 mm) noncombustible spacers 1” (25 mm) below 
ceiling.
4.  Chimney connector heat shields must extend to within 1” (25 mm) or less of the ceiling heat shield for installations venting straight up 
to a factory-built chimney.  In top exit installations using an elbow to vent to the rear, the chimney connector must be shielded over the 
entire vertical length.
5.  If a single-wall oval-to-round adapter is used, a shield must be used to protect combustibles to the rear of the adapter.
Stove and Chimney Connector Clearance Charts
Unprotected Surfaces
Protected Surfaces
Stove Clearance
Chimney Connector Clearance
Front Clearance to Combustibles