Procom ML200HBA 사용자 설명서

다운로드
페이지 21
1 2
OPERATING  YOUR  HEATER
NON-THERMOSTAT    MODELS
FOR YOUR SAFETY
READ BEFORE LIGHTING
   WARNING:  If  you  do  not  follow
these  instructions exactly,  a fire or
explosion  may  result   causing
property   damage,  personal  injury  or
loss   of   life.
A.   When  lighting  the  pilot,  follow  these
instructions  exactly.
B.     BEFORE  LIGHTING  smell  all
around  the  appliance  area  for  gas.
Be  sure  to  smell  next  to  the  floor
because  some  gas  is  heavier  than
air  and  will settle on  the  floor.
WHAT TO DO IF YOU SMELL GAS
 
  Do not  try  to  light  any
         appliance.
 
  Do    not    touch    any    electric
switch;  do  not  use any   phone
         in your building.
 
 Immediately   call    your   gas
supplier   from  a   neighbor’s
p h o n e .     F o l l o w     t h e     g a s
         supplier’s  instructions.
 
 if  you  cannot  reach  your gas
supplier,         call        the         fire
         department.
C.      Use  only   your  hand  to  push in
or  turn  the  gas  control  knob.
Never  use  tools.  If  the  knob  will
not  push  in  or  turn  by  hand,  don’t
try  to  repair  it , call  a  qualified
service  technician  or  gas  supplier.
Force  or  attempted  repair  may
result  in  a  fire  or  explosion.
D.     Do  not  use  this  appliance  if any
part  has  been  under  water.
Immediately  call  a  qualified  service
t e c h n i c i a n     t o     i n s p e c t     t h e
appliance  and  to  replace  any  part of
the  control  system  and  any gas
control  which  has  been   under   water.
LIGHTING
INSTRUCTIONS
1.      STOP!      Read        the      safety
         information,  on    the   side   of
         heater.
2.     Make  sure  equipment  shutoff
         valve  is  fully  open.
3.       Push   in   control     knob   slightly
and  turn   clockwise 
  to  the
        OFF position (see  Figure 19).
4.      Wait   five  minutes   to   clear    out
any gas. Then smell for gas,
including  near  the floor. If you
smell gas.STOP! Follow 
"
B
"
 in the
safety information  on  the side  of
        heater. If you can’t smell gas, go
to  the  next  step.
5.      Push  in  and   turn  control  knob
counterclockwise  
   to  PILOT
position.  Press  in  control knob
         for  five(5)  seconds.
         Note:   You    may   be    running
this  heater  for  the  first time
after  hooking  up  to  gas  supply.
If  so,  you  may   need  to  press
in  control  knob  for  30  seconds.
This  will  allow  air  to  bleed  from
        the  gas  system.
TO  TURN  OFF
GAS  TO  APPLIANCE
Shutting  Off  Heater
1.     Turn   control   knob  clockwise
        to  the  OFF  position.
2.     Turn  off  all  electric  power   to   the
       appliance  if  service  is  to
        be  performed.
Shutting  Off  Burner  Only  (pilot
stays  lit )
Slightly   press   in   control,   turn
control   knob clockwise  
  to the
PILOT   position.
Figure 19 - Control  Knob  in  The
OFF  Position
Figure 20 - Pilot
6.    With  control  knob  pressed  in,
push  down  and  release  the
ignitor  button. This  will  light
pilot. if  needed, keep  pressing
ignitor  button   until  pilot  lights.
7.    Keep  control  knob  depressed
for  ten(10)  seconds  after
lighting  pilot. If  pilot  goes  out,
repeat  steps 5,6  and  7.
8.   To  select  the  desired  heating
level, partially  press  down  the
control  knob  slightly  and  rotate
counterclockwise           . Release
the   downward  pressure  on  the
knob  while  continuing  to  turn
until  the  knob  locks at  the
desired  setting position. Do  not
o p e r a t e     b e t w e e n       l o c k e d
positions.
1.     Remove  lower  front  panel (see
Figure 7 page 7)
2.    Follow    steps   1   through   5
under  Lighting  Instructions .
3.      With     control     knob   pressed
in,  strike  match.  Hold  match  to
        pilot  until  pilot  lights.
4.      Keep   control   knob   pressed   in
for  30  seconds  after  lighting
pilot . After  30  seconds,  release
        control  knob. Follow step 8 under
Lighting  Instructions.
5.     Replace   lower  front   panel.
MANUAL    LIGHTING
PROCEDURE