Empire Comfort Systems BF-20-2 사용자 설명서

다운로드
페이지 20
Page 8
16943-5-0806
SRS-18* and SRS-30 Floor Stand Installation 
  1.  Align  clearance  holes  on  floor  stand  with  screw  holes  on 
bottom of heater, as shown in Figure 5.
  2.  Attach floor stand to heater with (4) screws provided with 
floor stand.
  3.  Connect the gas line.
  *   SRS-18  floor  stand  can  not  be  used  in  a  bedroom 
installation.
    BF-10 must be wall mounted in a bedroom installation.
Installation on Rugs and Tile
If this appliance is installed directly on carpeting, tile or other 
combustible material, other than wood flooring, the appliance shall 
be installed on a metal or wood panel extending the full width and 
depth of the appliance. 
Attention:    Optional  SRS-18  and  SRS-30  Floor  Stand  meets 
requirement.
The base referred to in this section does not mean the fire-proof  
base as used on wood stoves.  The protection  is for rugs that are 
extremely thick and light colored tile. 
Figure 5
BF-30
Figure 4
BF-10 and BF-20
Figure 3
When facing the front of the appliance the following minimum clearances to combustible construction must be maintained.
Do not install in alcove or closet.
Provide adequate clearances around air openings. 
Adequate accessibility clearances for purposes of servicing and proper operation must be provided.
BF-10/BF-20
BF-30
Left side
5" (127mm)
8" (203mm)
Right side
5" (127mm)
8" (203mm)
Rear wall
0" (0mm)
0" (0mm)
Ceiling
36" (914mm)
36" (914mm)
Minimum vertical clearance from a projections above 
the appliance (shelves, window sills, etc.)
36" (914mm)
36" (914mm)
Floor (top surface of carpeting, tile, etc.)
2" (51mm)
2" (51mm)
CLEARANCES
OPTIONAL FLOOR STAND INSTALLATION