Hampton Direct H25-NG1 사용자 설명서

다운로드
페이지 44
34
Hampton
®
 H25-1 Direct Vent Freestanding Gas Stove
WIRING DIAGRAMS
CAUTION:   Label all wires prior 
to disconnection when servicing 
controls. Wiring errors can cause 
improper and dangerous opera-
tion.
If any of the original wires as supplied with the 
appliance must be replaced, it must be replaced 
with CSA type SEW (200
o
C) or its equivalent.
This heater does not require a 120V A.C. sup-
ply for operation. In case of a power failure, the 
burner switch and the optional remote control/
thermostat will continue to operate. However, 
a 120V A.C. power supply is needed for the 
fan/blower operation.
Caution: Ensure that the wires do 
not touch any hot surfaces and are 
away from sharp edges.
INSTALLATION
FINAL CHECK
Before leaving this unit with the customer, the 
installer must ensure that the appliance is fi ring 
correctly. This includes:
1)  Clocking the appliance to ensure the cor-
rect fi ring rate (rate noted on label) at 15 
minutes.
2)  If required, adjusting the primary air to 
ensure that the fl ame does not carbon. 
First allow the unit to burn for 15 min. to 
stabilize.
3) Check 
for 
proper 
draft.
CAUTION
Any alteration to the product that causes 
sooting or carboning that results in damage 
to the exterior facia is not the responsibility 
of the manufacturer.
For 
NATURAL GAS
 Units and Units 
NOT
 Equipped with DC Spark Boxes