22
INSPECTING BURNERS
Check pilot flame pattern and burner flame pat-
terns often.
pILOT FLAME pATTERN
Figure 35 shows a correct pilot flame pattern. 
Figure 36 shows an incorrect pilot flame pattern. 
The incorrect pilot flame is not properly heating 
the thermocouple. When the thermocouple cools,
the heater will shut down.
If pilot flame pattern is incorrect, as shown in 
Figure 36
•  turn heater off (see To Turn Off Gas to Appli-
ance, page 20)
•  see Troubleshooting, page 24
Note:
 The pilot flame on a natural gas units will 
have a slight curve, but flame should be blue and 
have no yellow or orange color.
Figure 35 - Correct Pilot Flame Pattern 
Figure 36 - Incorrect Pilot Flame Pattern
Pilot Burner
Thermocouple
Thermocouple
Pilot Burner
Thermocouple
Pilot Burner
Thermocouple
Pilot Burner
Natural Gas Pilot
Propane/LP Gas Pilot
Natural Gas Pilot
Propane/LP Gas Pilot
BURNER pRIMARY AIR HOLES
Air is drawn into the burner through the holes in
the fitting at the burner entrance. These holes may 
become blocked with dust or lint. Periodically
inspect these holes for any blockage and clean if
needed. Blocked air holes will create soot.
MAIN BURNER
Periodically inspect all burner flame holes with the 
fireplace running. All slotted burner flame holes 
should be open with yellow flame present. All round 
burner flame holes should be open with a small blue 
flame present. Some burner flame holes may become 
blocked by debris or rust, with no flame present. If 
so, turn off fireplace and let cool. Remove blockage. 
Blocked burner flame holes will create soot. 
BURNER FLAME pATTERN
 WARNING: If yellow tipping 
occurs,  your  fireplace  could 
produce  increased  levels  of 
carbon monoxide.
NOTICE: Do not mistake orange 
flames with yellow tipping. Dirt 
or other fine particles enter the 
fireplace and burn causing brief 
patches of orange flame. 
Figure 37 shows a correct burner flame pattern. Fig-
ure 38 shows an incorrect burner flame pattern. The 
incorrect burner flame pattern shows the flame higher 
consistently higher than 1 inch above the logs.
If burner flame pattern is incorrect, as shown in 
Figure 38
•  turn heater off (see To Turn Off Gas To Appli-
ance, page 20)
•  see Troubleshooting, page 24
Figure 37 - Correct Burner Flame Pattern 
Yellow Tipping
Figure 38 - Incorrect Burner Flame Pattern