Desa LMFP33NR(B) 사용자 설명서

다운로드
페이지 36
www.desatech.com
119526-01A
4
SAFETy INFORMATION
Continued
6.  Do not add extra logs or ornaments such as
pine cones, vermiculite or rock wool. Using 
these added items can cause sooting. Do not
add lava rock around base. Rock and debris
could fall into the control area of fireplace.
7.  To prevent the creation of soot, follow the instruc-
tions in Cleaning and Maintenance, page 24.
8.  Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
9.  This fireplace needs fresh air ventilation to run 
properly. This fireplace has an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The 
ODS shuts down the fireplace if enough fresh 
air is not available. See Air for Combustion 
and Ventilation, page 5. If fireplace keeps 
shutting off, see Troubleshooting, page 25
.
10.  Do not run fireplace
• where flammable liquids or vapors are used 
or stored
• under dusty conditions
11.  Do not use this fireplace to cook food or burn 
paper or other objects.
12.  Do not use fireplace if any part has been exposed 
to or under water. Immediately call a qualified 
service technician to inspect the fireplace and to 
replace any part of the control system and any
gas control which has been under water.
13.  Do not operate fireplace if any log is broken. 
Do not operate fireplace if a log is chipped 
(dime-sized or larger).
14.  Turn fireplace off and let cool before servic-
ing. Only a qualified service person should 
service and repair fireplace.
15.  Operating fireplace above elevations of 4,500 
feet could cause pilot outage.
16.  To prevent performance problems in propane/LP
units, do not use propane/LP fuel tanks of less
than 100 lbs. capacity (propane/LP units only).
17.  Provide  adequate  clearances  around  air 
openings.
Figure 2 - Fireplace (LMFP33PR Shown)
Figure 1 - Log Base Assembly
O
F
F
  
PILO
  
O
N
 
4-Piece Log Set
(A Models shown)
Remote 
Receiver
Piezo 
Ignitor
Remote Control
Control 
Knob
Top Louver 
Assembly 
Firebox 
Hood 
Bottom Louver Assembly 
Screen 
Assembly 
Top Outer Casing 
Firebox 
Support 
Blower 
Assembly
(Optional)
LOCAL CODES
Install and use fireplace with care. Follow all local 
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code ANSI 
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note:
Where listed vented decorative logs are
required, thermostat operation is not permitted.
PRODUCT 
IDENTIFICATION