Desa LMFP33NR(B) 사용자 설명서
www.desatech.com
119526-01A
4
SAFETy INFORMATION
Continued
6. Do not add extra logs or ornaments such as
pine cones, vermiculite or rock wool. Using
these added items can cause sooting. Do not
add lava rock around base. Rock and debris
could fall into the control area of fireplace.
7. To prevent the creation of soot, follow the instruc-
tions in Cleaning and Maintenance, page 24.
8. Before using furniture polish, wax, carpet
cleaner or similar products, turn heater off. If
heated, the vapors from these products may
create a white powder residue within burner
box or on adjacent walls or furniture.
9. This fireplace needs fresh air ventilation to run
properly. This fireplace has an Oxygen Deple-
tion Sensing (ODS) safety shutoff system. The
ODS shuts down the fireplace if enough fresh
air is not available. See Air for Combustion
and Ventilation, page 5. If fireplace keeps
shutting off, see Troubleshooting, page 25
.
10. Do not run fireplace
• where flammable liquids or vapors are used
or stored
• under dusty conditions
11. Do not use this fireplace to cook food or burn
paper or other objects.
12. Do not use fireplace if any part has been exposed
to or under water. Immediately call a qualified
service technician to inspect the fireplace and to
replace any part of the control system and any
gas control which has been under water.
13. Do not operate fireplace if any log is broken.
Do not operate fireplace if a log is chipped
(dime-sized or larger).
14. Turn fireplace off and let cool before servic-
ing. Only a qualified service person should
service and repair fireplace.
15. Operating fireplace above elevations of 4,500
feet could cause pilot outage.
16. To prevent performance problems in propane/LP
units, do not use propane/LP fuel tanks of less
than 100 lbs. capacity (propane/LP units only).
17. Provide adequate clearances around air
openings.
Figure 2 - Fireplace (LMFP33PR Shown)
Figure 1 - Log Base Assembly
O
F
F
F
PILO
T
O
N
4-Piece Log Set
(A Models shown)
(A Models shown)
Remote
Receiver
Receiver
Piezo
Ignitor
Ignitor
Remote Control
Control
Knob
Knob
Top Louver
Assembly
Assembly
Firebox
Hood
Hood
Bottom Louver Assembly
Screen
Assembly
Assembly
Top Outer Casing
Firebox
Support
Support
Blower
Assembly
(Optional)
Assembly
(Optional)
LOCAL CODES
Install and use fireplace with care. Follow all local
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code ANSI
Z223.1/NFPA 54*.
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
Note:
Where listed vented decorative logs are
required, thermostat operation is not permitted.
PRODUCT
IDENTIFICATION