PRE-BURN CHECK: The burn pot liner holes must be clear and the liner installed properly against the 
ignitor tube and locked in place.  Check the hopper for enough pellets to start the unit.  
Note: 
Fuel Type can only be changed when the unit is cold. The thermostat mode can be changed during 
normal operation.
The unit has an automatic cleaning cycle; every thirty (30) minutes the agitator will turn continuously for 
one (1) minute to help clean out the burn pot liner. 
Figure 3: Thermostat Switch in 
MANUAL position.
Figure 4: Thermostat Switch in 
HIGH/LOW position.
Figure 5: Thermostat Switch in 
AUTO/OFF position.
FEED TRIM
ON/OFF
FUEL TYPE
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
PELLET
C-11256
MULTIFUEL
FEED TRIM
ON/OFF
FUEL TYPE
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
PELLET
C-11256
MULTIFUEL
1
2
3
4
5
6
7
MANUAL MODE:
All control of circuit board function is adjusted at the circuit board.
INITIAL START-UP: Press the ON / OFF button. The stove will 
turn on. The Fuel Type Light will flash (the Auger Feed Rate is pre-
programmed during start-up). The Heat Level Indicator will show the 
Heat Level that the stove will run at after start-up.
If this is the first time the unit has been started or the unit has run 
out of fuel, the auger may need to be primed. If there is no fuel in the burn pot after two (2) minutes 
press the Feed Trim button until fuel starts to drop into the Burn Pot Liner (see “O
PERATING
 I
NSTRUCTIONS
C
ONTROL
 B
OARD
 F
UNCTIONS
”). 
The agitator will not operate for the first five (5) minute after the ON button has been pressed. After the 
five (5) minutes it will pulse at the same interval as the feed auger.
When the start-up sequence is complete the unit will ramp up to its heat level setting, this may take up 
to ten (10) minutes.
Once a fire has been established, the convection blower will turn on after ten (10) minutes and the Fuel 
Type Light will turn solid. 
To OPERATE: Press the Heat Level buttons to change the desired Heat Level Output setting. 
The speed of the convection blower is controlled by the setting of the heat level. 
The Feed Trim button used in conjunction with the Heat Level adjustment buttons to adjust the Feed 
Trim. It can be increased by two (2) feed settings or it can be decreased by two (2) feed settings. 
HIGH/LOW MODE: (Requires a Thermostat or Timer)  
INITIAL START-UP: See MANUAL MODE above.
OPERATION:  When  the  thermostat  calls  for  heat  (contacts  are 
closed) the stove settings are adjustable as per Manual Mode.  When 
the thermostat contacts open, the HEAT LEVEL and Fans will drop 
down to the LOW setting until the thermostat contacts close again.  
The stove will come back to the previous HEAT LEVEL setting when 
the thermostat contacts close again.       
AUTO/OFF MODE: (Requires a Thermostat or Timer)  
INITIAL START-UP:  See MANUAL MODE above.
OPERATION:  When  the  thermostat  contacts  close,  the  unit  will 
light  automatically.  Once  up  to  temperature,  the  stove  operates 
the same as in MANUAL. When the thermostat contacts open, the 
stove’s HEAT LEVEL and Fans will drop down to the LOW setting for 
30 minutes. If the thermostat contacts close within the 30 minutes, 
FEED TRIM
ON/OFF
FUEL TYPE
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
PELLET
C-11256
MULTIFUEL
FEED TRIM
ON/OFF
FUEL TYPE
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
PELLET
C-11256
MULTIFUEL
1
2
3
4
5
6
7
FEED TRIM
ON/OFF
FUEL TYPE
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
PELLET
C-11256
MULTIFUEL
FEED TRIM
ON/OFF
FUEL TYPE
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
PELLET
C-11256
MULTIFUEL
1
2
3
4
5
6
7
8
Operating Instructions
the HEAT LEVEL will return to the previous MANUAL setting. If the thermostat contacts remain open, the 
stove automatically begins its shutdown routine. The stove will re-light when the thermostat contacts 
close again.