www.desatech.com
Gap Adjusting Screw
Rotor
Blade
.003"/.004" 
(.076-.101 mm)
Gap Measured 
With Feeler 
Gauge
Gap Adjusting Screw
Figure 30 - Gap Adjusting Screw 
Locations
Sandpaper
Figure 31 - Sanding Rotor
 
Note:
 If rotor is still binding, proceed as 
follows.
13.  Perform steps 1 through 6.
14.  Place fine grade sandpaper (600 grit) on flat 
surface. Sand rotor lightly in “figure 8” motion 
four times (see Figure 31).
15.  Reinstall insert and rotor.
16.  Perform steps 10 through 12.
Figure 32 - Replacing Fuse
Fuse Clips
Fuse 
Fuse 
Cover
SPECIFICATIONS
Model Size 
40 
55 
70 
115 
165
Output Rating (Btu/Hr) 
40,000 
55,000 
70,000 
115,000  165,000
Fuel 
Use only kerosene, #1/#2 diesel/fuel oil, JET A or JP-8 fuels*
Fuel Tank Capacity 
 
(U.S. Gal./Liters) 
3/11.3 
5/18.9 
5/18.9 
9/34 
13.5/51
Fuel Consumption 
(Gal. Per Hr/Liters Per Hr) 
.3/1.14  .44/1.67  .52/1.97  .85/3.00  1.2/4.54
Pump Pressure (psi) 
3.0 
3.4 
4.7 
5.1 
5.6
Electric Requirements 
120 V/60 HZ (Same All Models)
Amperage (Normal Run) 
2.0 
2.0 
2.8 
3.6 
3.6
Motor RPM 
1725 
1725 
3440 
3440 
3440
Hot Air Output (CFM) 
170 
180 
360 
490 
575
Shipping Weight 
32/14.5  35/15.9  35/15.9  54/24.5  65/29.5
(Approximate lbs./kg)
Heater Weight without Fuel  28/12.2  30/14 
30/14 
46/21 
55/25
(Approximate lbs./kg)
* Use of #2 diesel & fuel oil will result in noticeable odor and could require additional fuel filter main-
tenance. Use in extreme cold temperatures may require nontoxic anti-icer additives.
SERVICE PROCEDURES
Continued
IGNITION CONTROL ASSEMBLY
 WARNING: High voltage!
1.  Unplug heater.
2.  Remove side cover screws (4) using 5/16" nut-
driver to expose ignition control assembly.
3.  Remove fuse cover (see Figure 32).
4.   Remove fuse from fuse clips (see Figure 32).
5.  Replace fuse with fuse of the same type and 
rating (GMA-10). Do not substitute a fuse 
with a higher current rating.
6.   Replace fuse cover (see Figure 32).
7.  Replace side cover (see Figures 19 or 20, 