SAFETY INFORMATION
  WARNING:  This  product 
contains  and/or  generates 
chemicals  known  to  the  State 
of California to cause cancer or 
birth defects or other reproduc-
tive harm.
IMPORTANT: Read this owner’s 
manual carefully and completely 
before  trying  to  assemble, 
operate  or  service  this  heater. 
Improper use of this heater can 
cause  serious  injury  or  death 
from  burns,  fire,  explosion, 
electrical  shock,  and  carbon 
monoxide poisoning.
 DANGER: Carbon monoxide 
poisoning may lead to death!
Carbon  Monoxide  Poisoning:
  Early  signs  of 
carbon monoxide poisoning resemble the flu, with 
headaches, dizziness, and/or nausea. If you have 
these signs, the heater may not be working properly. 
Get fresh air at once! Have heater serviced. Some 
people are more affected by carbon monoxide than 
others. These include pregnant women, persons 
with heart or lung disease or anemia, those under the 
influence of alcohol, and those at high altitudes. 
Make certain you read and understand all warn-
ings. Keep this manual for reference. It is your 
guide to safe and proper operation of this heater.
1.  Use only kerosene, #1#2 diesel/fuel oil, JET A 
or JP-8 fuels to avoid risk of fire or explosion. 
Never use gasoline, naphtha, paint thinners, 
alcohol or other highly flammable fuels.
2.  Fueling
a) Personnel involved with fueling shall be 
qualified and thoroughly familiar with the 
manufacturerʼs instructions and applicable 
regulations  regarding  the  safe  fueling  of 
heating units.
b)  Only  the  type  of  fuel  specified  on  the 
heaterʼs data plate shall be used.
c) All flame, including the pilot light, if any, 
shall be extinguished and the heater allowed 
to cool, prior to fueling.
d) During fueling, all fuel lines and fuel-line 
connections shall be inspected for leaks. Any 
leaks shall be repaired prior to returning the 
heater to service.
e) At no time shall more than one dayʼs supply 
of heater fuel be stored inside a building in 
the vicinity of the heater. Bulk fuel storage 
shall be outside the structure.
f) All fuel storage shall be located a minimum 
of 25 feet (762 cm) from heaters, torches, 
welding  equipment,  and  similar  sources 
of  ignition  (exception:  the  fuel  reservoir 
integral with the heater unit).
g) Whenever possible, fuel storage shall be 
confined to areas where floor penetrations 
do not permit fuel to drip onto or be ignited 
by a fire at lower elevation.
h) Fuel storage shall be in accordance with the 
authority having jurisdiction.
3.  Use only the electrical voltage and frequency 
specified on model plate.
4.  Heater must be grounded. Use only a properly 
grounded three-wire extension cord. Plug into 
grounded outlet only.
5.  Use only in areas free of flammable vapors or 
high dust content.
6.  Minimum clearance from any combustible 
materials: 8 feet (244 cm) from hot air outlet; 
4 feet (122 cm) from top; and 4 feet (122 cm) 
from sides and inlet.
7.  Locate heater on a stable and level surface 
while hot or operating or a fire may occur.
8.  Use only in well-vented areas. Before using 
heater, provide at least a three-square-foot 
(2800 square cm) opening of fresh, outside air 
for each 100,000 Btu/Hr (30 kw) of rating.
9.  Keep children and animals away from heater 
at all times.
10.  Never start heater when combustion chamber 
is hot or if fuel has accumulated in combustion 
chamber.
11.  When used with thermostat, heater may start 
at anytime.
12.  When heater is moved or stored, it must be in 
a level position or fuel spillage may occur.
13.  Use  heater  only  in  accordance  with  local 
ordinances and codes.
14.  Never  use  gasoline,  crankcase  drainings, 
naphtha, paint thinners, alcohol or other highly 
flammable fuels.
15.  Never use heater where gasoline, paint thinner 
or other highly flammable vapors are present.