Aquacal 100 사용자 설명서
51
Controls Configuration & Adjustments...
Microprocessor Factory Default Settings
Level –1 and Level-2 Default Settings
Menu Code
Description
Default
Value
Range
Level-1
[CF1]
Celsius/Fahrenheit
1
0 / 1
Level-1
[ULC]
User Lock Code
0
0 / 1
Level-1
[ELC]
Enter Lock Code
0
00-99
Level-1
[CFO]
Call / Flex
0
0 / 1 / 2
Level-1 [LOC]
Service
Lock
Code
50
00-99
Mode Key
Pad
Operating
Mode
OFF
For Heat Only
OFF/HEAT
For Heat & Cool
OFF, HEA,
COO, ACH
COO, ACH
Thermostat
Key Pad
Thermostat Settings Pool & Spa
OFF
45
o
F – 104
o
F
Level-2
[dEL]
4-minute Delay on Make
1
0 / 1
Level-2
[JAO]
External Controller Interface
0
0 / 2 / 3
Level-2 [FS2]
Flow Switch / Auto T-Stat
Switching
0
0 / 1
Level-2 [tSC] Water
Sensor
Calibration
Factory
Calibrated
+10
o
to –10
o
of
displayed value
Level-2 [dSC] Defrost
Sensor
Calibration
Factory
Calibrated
+10
o
to –10
o
of
displayed value
Level-2
[dBS]
Spa Dead Band Differential
1
o
1
o
to 5
o
Level-2
[dBS]
Spa Dead Band Differential
1
o
1
o
to 5
o
Microprocessor Level-2 Set Up & Calibration Codes
Service Adjustable Parameters
Code Description Factory
Setting
Range
[LOC] Service
Lock
Code
50
00-99
[dEL]
4-minute Delay on Make
1
0 / 1
[JAO]
External Controller Interface
0
0 / 2 / 3
[FS2]
Flow Switch/Auto T-Stat Switching
0
0 / 1
[tSC]
Water Sensor Calibration
Factory Calibrated
+10
o
to –10
o
of display
[dSC]
Defrost Sensor Calibration
Factory Calibrated
+10
o
to –10
o
of display
[dBS]
Spa Dead Band Differential
1
o
1
o
to 5
o
[dBP]
Pool Dead Band Differential
1
o
1
o
to 5
o