Haier SAP-K18AM 사용자 설명서

다운로드
페이지 37
33
                
10.4  Tubing Length
Install unit within the maximum elevation
different (H) above or below the outdoor 
unit  and within a tatal tubing length (L) 
from the outdoor unit as detailed showed 
in Table 4 and Fig.37.
INDOOR
UNIT
Tubing length (L)
OUTDOOR
UNIT
Elevation
difference (H)
Fig. 37
10.6 Accessories
Table 5 listed the accessories supplied with the unit.
Table 4
*1 Standard tubing length is 5m for C18AGH & 7.5m for C18AM.
*2 If total tubing length becomes 5m / 7.5m to 25m, charge additional refrigerant (R22) acording to table 
    above. No additional charge of compressor oil is necessary.
Model
Max. Allowable Tubing
Length at Shipment
(m)*
1
Limit of Tubing
Length (L)
(m)
Limit of Elevation
Different (H)
(m)
Required Amount of 
Additional Refrigerant
(g/m)*
2
C18AM
7.5
7
30
25
C18AGH
5.0
7
30
25
10.  INSTALL OUTDOOR UNIT
Installation Service
Table 5 
*
 Packed in the outdoor unit
 Heat pump model only
#
Parts
Figure
Q’ty
Parts
Figure
Q’ty
Tapping
screw
AAA alkaline
battery
2
Remote
control unit
1
Remote control
holder
(Optional Part) 
1
Parts
Figure
Q’ty
Drain nozzle
*
1
Signal
control wire
Silver Ion 
filter 
1
Putty
1
4.2 x 25 mm
2
1
Ins. tube
FAN
OP
ER
ON
O
FF
C
ON/
OFF
F
A
N
-
+
MODE
CLOCK
TIM
ER
 O
N
BLOW
TEMP
TIM
ER
 OFF
TURB
O
SLEEP
LIGHT
10
#
#
Power
connection 
wire
1
#
Drain cap
*
3
10.5  Outdoor Condensation Drainage 
         (Heat Pump model only)
When the unit is heating and cooling type,
the condensing water and defrosting 
water can be drained out reliably through 
the drainage pipe.
How to install:
Install the outdoor drain nozzle in Ø 25  
hole on the base plate, and joint the drain
pipe to the drain nozzle, so that the waste 
water formed in the outdoor unit can be 
drained out to a proper place.(Fig.38)
Fig. 38
Chasis
Drain Nozzle
0
Flare Nut
1