READ ALL SAFETY INFORMATION BEFORE USING
1) All wiring must comply with local and 
national electrical codes and must be installed
by a qualified electrician. If you have any 
questions regarding the following instructions,
contact a qualified electrician. 
2) Check available power supply and resolve
any wiring problems BEFORE installing and
operating this unit.
3) This 115V air conditioner uses 10.0 or less
nameplate amps and may be used in any 
properly wired, general purpose household
receptacle. See Table 1 for specifications for
individual branch circuit.
4) For your safety and protection, this unit is
grounded through the power cord plug when
plugged into a matching wall outlet. If you are
not sure whether your wall outlet is properly
grounded, please consult a qualified electrician. 
5) The wall outlet must match the 3-prong plug
on the service cord supplied with the unit. DO
NOT use plug adapters. See Table 2 for 
receptacle and fuse information. If it is 
necessary to use an extension cord to connect
your air conditioner, use an approved “air 
conditioner” extension cord only 
(available
at most local hardware stores). 
6) The rating plate on the unit contains 
electrical and other technical data. The rating
plate is located on the right side of the unit,
above the power cord. 
TABLE 1
Suggested Individual Branch Circuit
Nameplate Amps
*AWG Wire Size
5.0 to 10
18
AWG- American Wire Gauge
*Based on copper wire at 60°C temperature rating.
TABLE 2
Receptacle and Fuse Types
Rated Volts
120
Amps
10
Wall Outlet
Fuse Size
15
Time Delay Fuse
Plug Type
(or Circuit Breaker)
3