Desa Tech CGD3018N 사용자 설명서

다운로드
페이지 32
27
102986
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at
1-800-DESA LOG (1-800-337-2564).
SPECIFICATIONS
18" Model
24" Model
30" Model
Btu (Variable)
16,000/30,000
20,000/39,000
20,000/39,0000
Type Gas
Natural Gas Only
Natural Gas Only
Natural Gas Only
Ignition
Piezo
Piezo
Piezo
Manifold Pressure
3.5" W.C.
3.5" W.C.
3.5" W.C.
Inlet Gas
Pressure (in. of water)
Maximum
10.5"
10.5"
10.5"
Minimum*
5"
Shipping Weight
28 lbs.
30 lbs.
32 lbs.
* For the purpose of input adjustment
When gas pressure is too low
• pilot will not stay lit
• burners will have delayed ignition
• heater will not produce specified heat
When gas quality is bad
• pilot will not stay lit
• burners will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local natural gas supplier.
SERVICE
HINTS