Installation 
(For Qualified Installers Only)
Travis Industries
4050418
1 0 0 - 0 1 1 5 6
Clearances - Straight Installation
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
6” Minimum
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
AAAAAAAA
3” Minimum
9” Minimum
3” 
Minimum
Through the Wall Installations
Interior Vertical Vents
A
A
A
A
A
A
Floor Protection
6” Minimum
2” 
Minimum
9” Minimum
“Tee”
Clearances - Corner Installation
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
AAAAAAAAAAAA
6” Minimum
AAAAAAAAAAAAA
AAAAAAAAAAAAA
AAAAAAAAAAAAA
AAAAAAAAAAAAA
AAAAAAAAAAAAA
AAAAAAAAAAAAA
AAAAAAAAAAAAA
AAAAAAAAAAAAA
AAAAAAAAAAAAA
AAAAAAAAAAAAA
AAAAAAAAAAAAA
AAAAAAAAAAAAA
AAAAAAAAAAAAA
Through the Wall Vents
A
A
A
A
A
A
3” Minimum
3” Minimum
45° Elbow
45°
3” Minimum
Interior Vertical Vents
3” 
Minimum
6” Minimum
2” 
Minimum
3” 
Minimum
Floor Protection
“Tee”
Note:
If interior vertical pellet vent is used, the clearance to the backwall is determined by the
upward-turning elbow or "Tee".  It will vary in depth depending on the brand of pellet vent
used (it is approximately 5").  Before placing the heater, connect the elbow or "Tee" and
measure off the 3" clearance.