Horizontal Installation
Standard Ceiling Installation
8)  To complete your chimney installation, install 
the double wall connector pipe from the 
stove’s fl ue collar to the chimney support 
device.  
9)  If you are using a horizontal connector, 
the chimney connector should be as high 
as possible while still maintaining the 18" 
(457mm) minimum  distance from the hori-
zontal connector to the ceiling.
10) NOTE: Residential Close Clearance and 
Alcove installations require a listed dou-
ble wall connector from the stove collar 
to the ceiling level.
The diagrams below illustrate one way to in-
stall your unit into a standard ceiling or with a 
horizontal connector. Check with your dealer 
or installer for information on other options 
available to you.
INSTALLATION
STEP-BY-STEP 
CHIMNEY AND 
CONNECTOR 
INSTALLATION
Note:    These are a generic set of chimney in-
stallation instructions.  Always follow 
the manufacturers own instructions 
explicitly. Verify the Minimum Recom-
mended Heights for Woodstove Flue 
(Table 1 in the Installation section).
1)  With your location already established, cut 
and frame the roof hole. It is recommended 
that no ceiling support member be cut for 
chimney and support box installation. If it is 
necessary to cut them, the members must 
be made structurally sound.
2)  Install radiant shield and support from 
above.
3)  Stack the insulated pipe onto your fi nish 
support to a minimum height of 3 feet above 
the roof penetration, or 2 feet above any 
point within 10 feet measured horizontally.  
There must be at least 3 feet of chimney 
above the roof level.
Note:    Increasing the chimney height above 
this minimum level will sometimes 
help your unit to “breathe” better 
by allowing a greater draft to be cre-
ated.  This greater draft can decrease 
problems such as, diffi cult start-ups, 
back-smoking when door is open, 
and dirty glass.  It might be suffi cient 
to initially try with the minimum re-
quired height, and then if problems 
do arise add additional height at a 
later date.
4)   Slide the roof fl ashing over your chimney 
and seal the fl ashing to the roof with roofi ng 
compound.  Secure the fl ashing to your roof 
with nails or screws.
5)  Place the storm collar over the fl ashing, 
sealing the joints with a silicone caulking.
6)  Fasten the raincap with spark screens (if 
required) to the top of your chimney.
7)  For optimum effi ciency when installing into 
a masonry chimney, size accordingly, i.e.  
the 6" (152mm) fl ue dia. is  28.28 sq.in. 
Leg and Bottom Shield Assembly
F2400M & S2400M
 Bottom 
Shield 
020-911
 
Legs (set of 4)
 
Steel - Painted Black 
850-125
 
Cast - Painted Black 
850-126
 
Cast - Gold Plated 
850-127
The instructions below apply to the steel leg, 
painted cast leg and the gold plated cast leg. It 
will be easier to attach the legs to the stove if 
the stove is tipped on its back (preferably on a 
soft surface to prevent scratching). Ensure to be 
extremely careful when tipping stove.
1)  Remove the 4 bolts from underside of the 
base of the pedestal and discard.  Also 
remove cover plate and put to the side.
2)  Line up the heat shield with the bottom of 
the unit.
3)  Start threading the bolt and washer (supplied 
with the bottom shield) for about 1/4 of the 
way through the leg with the washers being 
underneath the legs.  Ensure that the legs 
are properly aligned with heat shield and 
tighten the bolts.
4)  Level the stove by adjusting the levelling 
bolts in the bottom of each leg.
5) Reinstall 
cover 
plate.
6)  Install logo plate onto heat shield by placing 
in 2 holes as shown in diagram.
If you are installing outside combustion air, bend 
the tabs out 90 degrees. Pipe fresh air into the 
bottom shield by using a minimum 4" duct pipe 
with a mesh grill at the outside termination. At-
tach the pipe to the 2 tabs with screws.