INSTALLATION
DV STOVE HORIZONTAL FLUE KIT (# 946-112) INSTALLATION
Minimum Installation Height:
F39: 59-3/4" ( 1518mm)
Review the following sequence of instructions 
which are typical of most installations. The 
sequence may vary depending on wall thick-
ness. Refer to  fl ue location, see "Exterior 
Flue Termination Location" section.
  and 
clearance dimensions, see to "Clearances 
to Combustibles" section. 
1)  Set the unit in its desired location. Check 
to determine if wall studs will be in the way 
of the fl uing system, adjust location until 
all clearances are met and there are no 
obstructions.
Note:  A 1-1/2"(38mm) clearance around 
the outer pipe must be maintained 
except that only a 1" (25mm) clear-
ance is needed at the termination 
end. 
IMPORTANT:
Do not locate termination hood where 
excessive snow or ice buildup may occur. 
Be sure to check fl ue termination area after 
snow falls, and clear to prevent accidental 
blockage of fl uing system. When using 
snow blowers, make sure snow is not directed 
towards fl ue termination area.
2) Assemble 
trial fi t to determine the verti-
cal center-line for the fl ue termination.
 
a)  Cut a  241mm round hole on both the 
interior and exterior wall.
 
b)  Attach the 2 ft. pipe section to the fl ue 
terminal and slide into position from 
the exterior. The larger diameter end 
of the adjustable pipe goes to the 
fl ue terminal.
 c) 
Install 
the 
90
o
 elbow onto the adjust-
able pipe to determine the vertical 
centerline of the starter collar on the 
unit. 
 
 
Note: if the centerline cannot be 
met, the adjustable sections will 
have to be cut.
 
d)  Cut the 2 ft. section of rigid pipe to 
length. Ensure that the pipe length 
DV STOVE HORIZONTAL FLUE KIT
Horizontal Stove Flue Kit (Part # 946-112) includes all the parts needed to install the F39 Freestand-
ing Gas unit with  minimum horizontal and vertical vent dimensions. For installations that require 
longer vertical and/or horizontal vents use the Dura-Vent system as shown in your manual.
    Qty. 
Description
1) 
2 Rigid Pipe Section 1.2m length,  165mm inside diameter 
2) 
1 Flex Liner, compressed aluminium 2 ply liner, 102mm inside diameter
3) 4 
spring 
spacers
4) 
1 90 deg. Elbow
5) 
1 Decorative Wall Trim
6) 1 
Adapter 
7) 1   AstroCap Termination Cap
8) 2   Trim 
Collar
9)  1    tube of Mill-Pac, high temperature sealant
10) 12    Screws, #8 x 1/2" Self tapping, Stainless Steel
11) 14    Screws, #8 x 1/2" Self tapping, Black
12) 4    Screws #8 x 1-1/2" Drill Point, Stainless Steel
Optional:
946-206  Vinyl Siding Standoff 
 
 for AstroCap
Note: 
a)  Liner sections should be continuous 
without any joints or seams.
b)  This is an approved system, therefore 
components in this system must not be 
substituted for any other manufacturer's 
products.
c)  Wall Thimble is required when installing 
through a combustible wall.