ULTRA FLAME DIRECT VENT GAS STOVE 
 
Burner 
 
Natural Gas 
Propane LP 
Maximum Input, BTU/h (kW) 
minimum : 
 maximum 
 
20 000 
(5,9)  
 30 
000 
(8,8) 
 20 
000 
(5,9)
 26 
000 
(7,6) 
Inlet Pressure INWC (kPa) 
minimum : 
 maximum 
 5,0 
(1,3) 
 7,0 
(1,8) 
 11,0 
(2,8) 
 14,0 
(3,5) 
Manifold Pressure INWC (kPa) 
minimum : 
 maximum 
 1,8 
 (0,5) 
 3,5 
 (0,9) 
 7,0 
(1,8)
 10,0 
(2,5) 
Burner orifice, 
∅ : 
36 52 
Injecteur du pilot. 
∅ : 
51 30 
Gas Valve SIT 820 Nova mV 
Natural Gas 
Propane LP 
Gas Valve : 
Model SIT 0.820.634 
Nova mV 
Model SIT 0.820.633 
Nova mV 
 
Your stove is equipped with a sophisticated gas control valve, which will give you a safe use of your appliance. 
The gas control valve SIT 820 Nova mV operates without electricity due to the energy given by the pilot flame 
and captured by the thermo-generator. (also called thermopile). The admission of the gas fuel to the burner is 
done only under safe conditions. 
Pressure Adjustments 
•  Adjustments to the valve assembly must be performed by a qualified service person. 
•  The appliance and its individual shutoff valve must be disconnected from the gas supply piping system 
during any pressure testing of that system at test pressures in excess of ½ psi (3.5 kPa); 
•  The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff 
valve during any pressure testing of the gas supply piping system at test pressures equal to or less that ½ 
psi (3.5 kPa); 
NATURAL GAS 
The inlet supply or line pressure must be a minimum of 5 INWC and a maximum of 7 INWC. The orifice has a 
#36 hole. 
ELEVATION INPUT 
RATING 
0-4500 ft (0-1400m) 
30 000 BTU/h  (8.8 kW) 
over 4500 ft (1400 m) + 
30 000 BTU/h  (8.8 kW) less 4% per 1000 ft (300 m) 
 
or reduce manifold pressure by 0.25 INWC per 1000 ft (300 m) 
GAZ PROPANE 
The inlet supply or line pressure must be a minimum of 10.5” WC and a maximum of 12” WC.  The orifice 
has a #52 hole. 
ELEVATION INPUT 
RATING 
0-4500 pi (0-1400 m) 
26 000 BTU/h  (7.6kW) 
4500 pi (1400m)+ 
26 000 BTU/h  (7.6kW) moins 4% par 1000 pi (300m) 
 
or reduce manifold pressure by 1 INWC per 1000 ft 
NOTE : The input rating should always be checked when first running this appliance. To do this, verify inlet 
valve pressure and manifold pressure,. Adjust manifold pressure to meet values range as indicated in burner 
characteristics table.