Lightolier 2001 전단

다운로드
페이지 2
Lightolier 
a Genlyte company 
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • C1007
Job Information 
Type:
Lytecaster
®
 Performance Recessed CFL Downlighting 
2001
Page 2 of 2 
3 ¾" Aperture Vertical Open, Compact Fluorescent, Performance Series, Reflector Trim
18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
13W TRIPLE TUBE LAMP, LUMEN RATING = 900 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
1
56
113
169
225
60˚
30˚
13W QUAD TUBE LAMP, LUMEN RATING = 900 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
1
50
100
150
200
60˚
30˚
COEFFICIENTS OF UTILIZATION
Ceiling
80%
70% 
50%
30%
Wall
70 50 30 10 50 10 50 10 50 10
0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Room 
Cavity 
Ratio
0 61  61  61  61  60  60  57  57  55  55  52
1 58  56  54  53  55  52  53  50  51  49  47
2 54  51  48  46  50  45  48  44  46  43  41
3 50  46  42  40  45  39  44  39  42  38  37
4 46  41  38  35  41  35  40  34  38  34  32
5 43  38  34  31  37  31  36  30  35  30  29
6 40  34  30  27  34  27  33  27  32  27  26
7 37  31  27  24  31  24  30  24  29  24  23
8 35  29  25  22  28  22  28  22 27  22  21
9 33  26  22  20  26  20  25  20  25  20  19
10 31  24  21  18  24  18  24  18  23  18  17
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 17.0
ZONAL LUMENS AND PERCENTAGES
Zone
Lumens %Lamp
%Fixt
0-30
175.46 
19.5 
37.8
0-40
294.57 
32.7 
63.5
0-60
458.58 
51 
98.8
0-90
464.18 
51.6 
100
90-120
0
90-130
0
90-150
0
90-180
0
 0
 0
0-180
464.18 
51.6 
100
**  Efficiency = 51.6%** 
ZONAL LUMEN SUMMARY
Zone
Lumens
0-10
19.02
10-20
60.03
20-30
96.41
30-40
119.11
40-50
113.45
50-60
50.56
60-70
 5.48
70-80
.13
80-90
0
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
CANDLEPOWER SUMMARY
Angle
0˚ CP
190
195
10 
207
15
212
20 
213
25 
209
30 
202
35 
191
40 
175
45 
151
50 
108
55 
53
60 
18
65 
3
70 
1
75
0
80 
0
85 
0
90 
0
SC = 1.5
CERTIFIED TEST REPORT NO. 3040FR
COMPUTED BY LSI PROGRAM 
**TEST-LITE**
COEFFICIENTS OF UTILIZATION
Ceiling
80%
70% 
50%
30%
Wall
70 50 30 10 50 10 50 10 50 10
0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Room 
Cavity 
Ratio
0 53  53  53  53  52  52  50  50  48  48  45
1 50  49  47  46  48  45  46  44  44  43  41
2 47  44  42  40  43  39  42  38  40  38  36
3 44  40  37  35  39  34  38  34  37  33  32
4 40  36  33  30  35  30  34  30  33  29  28
5 37  33  29  27  32  27  31  26  30  26  25
6 35  30  26  24  29  24  29  24  28  23  22
7 32  27  24  21  27  21  26  21  26  21  20
8 30  25  22  19  25  19  24  19  24  19  18
9 28  23  20  17  23  17  22  17  22  17  16
10 27  21  18  16  21  16  21  16  20  16  15
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 16.0
ZONAL LUMENS AND PERCENTAGES
Zone
Lumens %Lamp
%Fixt
0-30
55.05 
17.2 
38.4
0-40
257.28 
28.6 
63.7
0-60
399.05 
44.3 
98.8
0-90
403.78 
44.9 
100
90-120
0
90-130
0
90-150
0
90-180
0
0-180
403.78 
44.9 
100
**  Efficiency = 44.9%** 
CANDLEPOWER SUMMARY
Angle
0˚ CP
174
10 
179
15
183
20 
182
25 
187
30 
187
35 
179
40 
164
45 
146
50 
126
55 
97
60 
48
65 
17
70 
2
75
0
80 
0
85 
0
0
0
ZONAL LUMEN SUMMARY
Zone
Lumens
0-10
17.21
10-20
52.09
20-30
85.75
30-40
102.22
40-50
 95.83
50-60
45.94
60-70
4.74
70-80
0
80-90
0
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
SC = 1.4
CERTIFIED TEST REPORT NO. 3039FR
COMPUTED BY LSI PROGRAM 
**TEST-LITE**
1
75
150
225
300
60˚
30˚
SC = 1.5
CERTIFIED TEST REPORT NO. 3038FR
COMPUTED BY LSI PROGRAM 
**TEST-LITE**
COEFFICIENTS OF UTILIZATION
Ceiling
80%
70% 
50%
30%
Wall
70 50 30 10 50 10 50 10 50 10
0
RCR
Zonal Cavity Method - Effective Floor Reflectance = 20%
Room 
Cavity 
Ratio
0 56  56  56  56  55  55  53  53  50  50  47
1 53  52  50  49  50  48 49  47  47  45  43
2 50  47  44  42  46  42  44  41  43  40  38
3 46  42  39  37  42  37  40  36  39  35  34
4 43  38  35  32  38  32  37  32  36  31  30
5 40 35  31  29  34  28  33  28  32  28  27
6 37  32  28  25  31  25  30  25  30  25  24
7 35  29  25  23  29  23  28  23  27  22  21
8 32  27  23  21  26  21  26  20  25  20  19
9 30  24  21 19  24  19  24  18  23  18  18
10 28  23  19  17  22  17  22  17  22  17  16
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 22.0
ZONAL LUMENS AND PERCENTAGES
Zone
Lumens %Lamp
%Fixt
0-30
222.19 
18.5 
39
0-40
370.28 
30.9 
65.1
0-60
564.67 
47.1 
99.2
0-90
569.15 
47.4 
100
90-120
0
90-130
0
90-150
0
90-180
0
 0
 0
0-180
569.15 
47.4 
100
**  Efficiency = 47.4%** 
ZONAL LUMEN SUMMARY
Zone
Lumens
0-10
23.94
10-20
75.59
20-30
122.65
30-40
148.09
40-50
136.28
50-60
58.12
60-70
4.48
70-80
.0
80-90
0
90-100
0
100-110
0
110-120
0
120-130
0
130-140
0
140-150
0
150-160
0
160-170
0
170-180
0
CANDLEPOWER SUMMARY
Angle
0˚ CP
239
246
10 
260
15
266
20 
271
25 
267
30 
255
35 
238
40 
215
45 
180
50 
130
55 
59
60 
19
65 
1
70 
0
75
0
80 
0
85 
0
90 
0