Lightolier WMRL124120SB 전단

다운로드
페이지 2
Walmaster
WMRL124120SB
Page 2 of 2
High Performance, 2', Recessed Wallwasher/Accent Light
One Twin Tube T5 Lamp 
Lightolier 
a Genlyte Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 a Genlyte company
Section5/Folio K10-15 Rev. A
Job Information
Type:
Ordering Information
Explanation of Catalog Number. Example: WMRL124120SBGLR
Options/Accessories
Fusing: Internal fast-blow fusing. Suffix: GLR.
Internal slow-blow fusing. Suffix: GMF.
Radio Interference Filter: To order one RIF per fixture, Suffix: R
To order one RIF per ballast. Suffix: B.
Electrical/Wiring Options: Consult factory.
Fluorescent Emergency Lighting System: Factory-installed emergency power
battery pack with charger and inverter. Suffix: EM.
Drywall Frame: Catalog Number: WL2DF/UNV.
Specifications
Materials: Chassis parts are die-formed 20 gauge cold rolled steel with
integral adjustable hanger clamp. Reflectors–low iridescent semi- specular 
aluminum are standard.
Finish: Chassis exterior–phosphate undercoating, baked white acrylic
enamel. Reflector–low iridescent semi-specular is standard. 
Electrical: Rapid start HPF, thermally protected class “P” ballast (Biax type). If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.
Photometry
Model No. WMRL124120SB
WM
Wal-Master:
Low iridescent
semi-specular
wallwash
R
Recessed
L
Reflector:
= Low iridescent
semi-specular 
aluminum
1
Lamp
2
Length:
2=24"
Watts:
1=18 Watts
2=24 Watts
4=40 Watts
5=50 Watts
6=55 Watts
Voltage:
120 or 277
Options:
Add appropriate
suffix to catalog
no, ie: (GLR)
LER = FP - 43.0   IW - 45.1   BF - 0.95
Comparative yearly lighting energy cost per 1000 lumens = $5..58
coefficients of utilization — zonal cavity method  
RF
20
20
20
RC
80
50
30
RW
70
50
30
50
30
10
50
30
10
1
70
67
65
63
61
59
61
59
57
2
64
59
54
55
52
49
53
50
48
3
58
51
46
48
44
41
47
43
40
4
53
45
40
43
38
35
41
37
34
5
49
41
35
38
34
30
37
33
29
6
45
36
31
35
30
26
34
29
26
7
42
33
27
31
27
23
30
26
23
8
39
30
24
29
24
20
28
23
20
9
36
27
22
26
22
18
26
21
18
10
34
25
20
24
20
17
24
19
16
room cavity ratio
FOOTCANDLES ON WALL  
Fixtures 3 feet from wall to outside trim on lamp side of fixture
0'
1'
2'
3'
4'
5'
6'
7'
0
4'
6'
0'
1'
2'
3'
4'
5'
6'
7'
8'
Ceiling
8'
52
41 24
13
0
8
6
5
4
71
64
56
64
71
61
51
35
29
35 51
61
119 122 123 124 124 124 123 122 119
7'
56
48 32
19
12
8
6
5
83
79
74
79
83
66
60
47
41
47 60
66
144 149 152 153 153 153 152 149 144
6'
43
39 29
19
13
9
7
5
72
70
69
70
72
54
51
45
41
45 51
54
125 131 134 136 136 136 134 131 125
5'
32
30 24
18
13
9
7
6
60
60
60
60
60
44
42
40
38
40 42
44
105 109 113 114 115 114 113 109 105
4'
24
23 20
15
12
9
7
6
50
50
50
50
50
35
34
35
33
34 34
35
0
86
0
91
0
94
0
95
0
96
0
95
0
94
0
91
0
86
3'
19
18 16
11
11
9
7
6
41
41
41
41
41
28
28
28
28
28 28
28
0
71
0
74
0
77
0
78
0
78
0
78
0
77
0
74
0
71
2'
15
14 13
11
0
9
8
7
6
34
34
34
34
34
24
24
24
24
24 24
24
0
58
0
61
0
63
0
64
0
65
0
64
0
63
0
61
0
58
1'
12
12 11
10
0
8
7
7
6
28
28
28
28
28
20
20
20
20
20 20
20
0
47
0
50
0
51
0
52
0
52
0
52
0
51
0
50
0
47
Floor
INDIVIDUAL WAL-LYTER
MULTIPLE UNITS
CONTINUOUS ROW
Ballast Type:
<
20THD
<
10THD
1 Lamp Magnetic (TT5)
BX*
(40 Watt)
1 Lamp Electronic (TT5)
BA
*
(18 Watt)
1 Lamp Electronic (TT5)
BB
*
(24 Watt)
1 Lamp Electronic (TT5)
SB*
I
B*
(40 Watt)
1 Lamp Electronic (TT5)
BE
*
BP
(50 Watt)
1 Lamp Electronic (TT5)
-
*
BF
(55 Watt)
LOL (TT5) Dimming
PB*
*
(40 Watt)
*Instant Start Standard
optional drywall frame WL2DF/UNV.