Lightolier DRL35 전단

다운로드
페이지 2
8292WE
0400
Lytespan® Track Lighting System 
drL35
Page 1 of 2 
Director
®
 Metal Halide 39W T6
Lightolier 
a Genlyte company 
www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2007 Genlyte Group LLC • B0507
Job Information 
Type:
AIMINg ANgLE 
L  Beam Length
W  Beam Width
C  Distance to center beam
d  Distance
A  Aiming Angle
FC  Footcandles
L and W are the outer points where the candle power 
drops to 50% of the maximum. FC are the initial footcandles 
at  the center of the beam.
Lamp data shown is typical. Consult lamp manufacturers 
for availability and performance.
Lamp Information:
39W T6 Clear Ceramic Metal Halide
Initial Lumens:  3300
CRI: 
81
Rated Avg. Life:  9,000 to 12,000 hrs.
0˚ 
30˚ horizontal
30˚ Vertical
45˚ Vertical
 
  8' 
174 
2.2' 
2.2' 
8' 
4.6' 
113  3.0' 
2.6' 
2' 
3.5' 
347 
2.4' 
1.1' 
3' 
3.0'  436 
1.7'  1.2'
  10' 
111 
2.8' 
2.8' 
10' 
5.8' 
72  3.8' 
3.2' 
3' 
5.2' 
154 
3.6' 
1.7' 
4' 
4.0'  245 
2.3'  1.6'
  12' 
77 
3.4' 
3.4' 
12' 
6.9' 
50  4.5' 
3.9' 
4' 
6.9' 
87 
4.8' 
2.2' 
5' 
5.0'  157 
2.9'  2.0'
  14' 
57 
3.9' 
3.9' 
14' 
8.1' 
37  5.3' 
4.5' 
5' 
8.7' 
56 
6.0' 
2.8' 
6' 
6.0'  109 
3.4'  2.4'
AIMINg ANgLE:
 
0˚ horizontal Aiming 
30˚ horizontal Aiming 
30˚ Vertical Aiming  
45˚ Vertical Aiming 
  d 
FC 
FC  L 
FC 
FC 
W
 
Beam Spread
 
(To 50% CBCP) 
CBCP
  d 
FC 
FC  L 
FC 
FC 
W
 
Beam Spread
 
(To 50% CBCP) 
CBCP
DRT6RS Spot
Reflector
11,108
  6' 
214 
2.6' 
2.6' 
6' 
3.5' 
139  3.5' 
2.9' 
2' 
3.5' 
241 
3.9' 
1.7' 
3' 
3.0'  306 
2.7'  1.8'
  8' 
121 
3.4' 
3.4' 
8' 
4.6' 
78  4.6' 
3.9' 
3' 
5.2' 
107 
5.9' 
2.6' 
4' 
4.0'  172 
3.6'  2.4'
  10' 
77 
4.3' 
4.3' 
10' 
5.8' 
50  5.8' 
4.9' 
4' 
6.9' 
60 
7.9' 
3.4' 
5' 
5.0'  110 
4.5'  3.0'
  12' 
54 
5.1' 
5.1' 
12' 
6.9' 
35  6.9' 
5.9' 
5' 
8.7' 
39 
9.8' 
4.3' 
6' 
6.0' 
76 
5.3 
3.6'
DRT6RM Med
Flood Reflector
7,712
16° x 16°
24° x 24°
  d 
FC 
FC  L 
FC 
FC 
W
 
Beam Spread
 
(To 50% CBCP) 
CBCP
  6' 
216 
3.9' 
3.9' 
8' 
4.6' 
79  7.2' 
6.0' 
2' 
3.5' 
243 
7.6' 
2.6' 
3' 
3.0'  306 
4.4'  2.8'
  8' 
122 
5.2' 
5.2' 
10' 
5.8' 
51  9.0' 
7.5' 
3' 
5.2' 
108  11.4'  3.9' 
4' 
4.0'  172 
5.8'  3.7'
  10' 
78 
6.5' 
6.5' 
12' 
6.9' 
35  10.8' 
9.0' 
4' 
6.9' 
61 
15.2'  5.2' 
5' 
5.0'  110 
7.3'  4.6'
  12' 
54 
7.8' 
7.8' 
14' 
8.1' 
26  12.6' 
10.5' 
5' 
8.7' 
39 
19.0'  6.5' 
6' 
6.0' 
76 
8.7'  5.5'
DRT6RF Flood 
Reflector
7,779