HAZARDLINE ENCLOSED INDUSTRIAL
HSCXT SERIES
Page 4 of 4
CLASS I, DIVISION 2 LOCATIONS, GROUPS A,B,C,D; CLASS II, DIVISION I AND 2 
GROUPS F AND G; CLASS III, DIVISION I, DIVISION 2 LOCATIONS, WET LOCATIONS
Lightolier 
a Genlyte Thomas Company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2002 Genlyte Thomas Group LLC (Lightolier Division)
A0902
Section 7/Folio Q10-33
Job Information
Type:
SPECIFICATIONS
MATERIALS: Chassis is non-corrosive one-piece seamless molded fiberglass
reinforced polyester composite body suitable (T8 or T12 RS) for 40°C ambient
temperatures, with 1/2" NPT (2 on top of body and 1 at each end of body, fully
gasketed and fastened to body with two 1/4-20 machine screws and lockwash-
ers within the fixture body.
WIREWAY: Full-length rigidly formed wireway cover with all electrical compo-
nents retained to body with captive screws for easy removal and can be 
suspended with safety-chains for convenient handling and service.
FINISH: Body—white polyester composite with 85% minimum reflectivity.
Power Channel/Reflector–phosphate primed, baked white acrylic enamel
with minimum 86% reflectivity.
LENS FRAME: Stainless steel, non-corrosive 16-gauge steel frame gasketed
with silicone, securely attached to frame. Hinges both sides. 
LENS: 3/16" thick tempered glass.
LENS FRAME CLAMPS: Stainless spring steel toggle clamps.
ELECTRICAL: Thermally protected class “P” ballast C.B.M. approved, non PCB.
If K.O. is within 3" of ballast, use wire suitable for at least 90°.
LABELS: I.B.E.W./UL and C-UL.
ORDERING INFORMATION
Explanation of Catalog Number.   Example: HSCXT232120SOCW
HSC
HAZARDLINE:
Enclosed
Industrial
Fluorescent 
NUMBER OF
LAMPS IN WIDTH:
2 or 3 Lamps
(No 3 lamp 48HO)
BALLAST TYPE:
<20THD
<10THD
1-2 Lamp Elec. T8
SO*
H
I
*
1-3 Lamp Elec. T8
O3*
H3*
OPTIONS:
Add appropriate
suffix to catalog
no., ie: (CW)
XT
Class I, Division 2
Class II, III
32
LAMP/FIXTURE
LENGTH:
32 = T8
(Nominal 48")
VOLTAGE:
120 or 277
OPTIONS/ACCESSORIES
COLD WEATHER BALLASTS
: HO fixtures are standard
with -20°F ballasts. To specify cold-weather (O°F) ballasts
for RS fixtures, SUFFIX: 
CW
.
45° ADJUSTABLE STAINLESS STEEL
QUADRANT BRACKETS
: Two sturdy “L”
type adjusta-mounts with gaskets for field
installation at top and side ends of fixture.
Permit housing to be permanently surface-
mounted and adjusted up to 45° in either
direction in 5° increments. Provide wide-
spread directed illumination where tasks
are not fixed. Specify Bracket Catalog
Number: 
NKH45.
THERMAL PERFORMANCE OF HSCXT FIXTURES*
Catalog
Lamps
Ambient
“T”
Fixture
Number
Quantity
Type
Temp. °C
Numbers
Temperature*
HSCXT132
2
T8
40
T-4A
120°C (248°F)
HSCXT332
3
T8
40
T-4A
120°C (248°F)