Lightolier EYS414FR254 전단

다운로드
페이지 2
0.0
45.0
90.0
FLUX
0
1547
1547
1547
5
1534
1526
1542
146
15
1425
1428
1434
403
25
1241
1242
1268
575
35
1034
1034
1205
674
45
797
872
1211
729
55
545
753
1058
678
65
283
522
776
513
75
130
269
372
271
85
30
90
42
78
90
4
60
13
95
19
32
15
32
105
35
70
56
62
115
48
90
103
86
125
61
121
120
93
135
73
129
149
91
145
84
115
116
72
155
94
104
117
49
165
102
102
106
29
175
105
98
98
10
180
100
100
100
Eye-QLB 
EYS414FR254
Page 2 of 2
14  Cell Louver, 90% Downlight, 10% Uplight
48" Length 2 Lamp T5/T8,  96" Length 2 Lamp T5/T8 in Tandem
Job Information
Type:
Ordering Information
Explanation of Catalog Number. Example: EYS414FR232UNVHI
Options/Accessories
Stem and Canopy Sets: Suspends fixture 6", 12", 18" or 24" from surface.
Catalog Number: ASC6 CSP (6"), ASC12 CSP (12"), ASC18 CSP (18"),
ASC 24 CSP (24").
Fusing: Internal fast blow fusing: SUFFIX: GLR.
Internal slow blow fusing: SUFFIX: GMF.
Emergency Pack: Factory-installed emergency power battery pack with
charger and inverter. SUFFIX: LP400 (T8). LP550 (T5).
Cable Hangers: Adjustable 6"-60".
Single Cable and Canopy: Catalog Number: WC60.
Single Cable, Straight Cord and Canopy: Catalog Number: WCC60**.
Single Cable, Coil Cord and Canopy: Catalog Number: WCCC60**.
Chain Hanger Kits: Catalog Number: AH5 CSP.
**Cord, 3-#18 wires.
Specifications
Materials: Housing is die-formed 20 gauge cold rolled steel with full length
channel for thru wiring..
Fixture Ends: 18 gauge cold rolled steel.
Louver: 22 gauge cold rolled steel.
Side Reflectors: Solid 22 gauge cold rolled steel.
Finish: Post painted white acrylic baked enamel.
Specifications (continued)
Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If
K.O. is within 3" of ballast, use wire suitable for at least 90°.
UL Listed for damp locations.
Labels: I.B.E.W./UL and ULc Listed.
EY
Options:
Add appropriate
suffix to catalog
no., ie: (GLR)
Eye-Q LB:
Suspended/
Surface
Fluorescent
Luminaire
S
S=Solid
Sides
Fixture
Length:
4=48"
8=96"
Lamp Type:
(By Others)
32=T8
28=T5
54=T5
(Nominal 48")
R
R= 10% Uplight
Reflector
Model No. EYS414FR232UNVHI
LER = FP - 67.3
IW - 59.7
BF - 0.87
Comparative yearly lighting energy cost per
1000 lumens = $3.58
Report Number: G2005315
Catalog Number: EYS414FR232UNVHI
Lamps: F32T8
Luminaire: Eye-Q LB with solid sides, 14
cell flat white louver and 10% uplight
specular reflector
Ballast: B232IUNVHP-B-Triad
Report is based on 2850 Lumens per lamp.
Efficiency: 80.6%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.1
1.2
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
48.000
9.000
Height of Side:
3.960
3.960
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
3735.
3507.
4266.
55
3049.
3429.
4063.
65
2041.
2839.
3388.
75
1377.
1887.
1951.
85
635.
929.
287.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 86 82 78 74 71 69 69 67 65
0
2 78 71 66 65 61 57 61 57 54
0
3 71 62 56 57 52 48 53 49 46
0
4 65 55 48 50 45 41 47 43 39
0
5 60 49 42 45 39 35 43 38 34
0
6 55 44 37 41 35 31 39 34 30
0
7 51 40 33 37 31 27 35 30 26
0
8 47 37 30 34 28 24 32 27 24
0
9 44 34 27 31 26 22 30 25 21
10 41 31 25 29 23 20 27 23 19
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
1124
19.7
24.5
0
0-
0
40
1798
31.5
39.2
0
0-
0
60
3206
56.2
69.8
0
0-
0
90
4067
71.4
88.6
90-120
180
3.2
3.9
90-130
274
4.8
6.0
90-150
437
7.7
9.5
90-180
525
9.2
11.4
9
0
0-180
4592
80.6
100.0
ZONAL LUMEN SUMMARY
Model No. EYS414FR254UNVPG
LER = FP - 69.1
IW - 118.5
BF - 1.00
Comparative yearly lighting energy cost per
1000 lumens = $3.48
Report Number: G2005307
Catalog Number: EYS414FR254UNVPG
Lamps: FP54/835
Luminaire: Eye-Q LB with solid sides, 14
cell flat white louver and 10% uplight
specular reflector.
Ballast: B254-IUNV-E Universal
Report is based on 4400 Lumens per lamp.
Efficiency: 93.3%
CIE Type-Direct-Indirect
Plane:
0-Deg
90-Deg
Spacing Criteria:
1.1
1.1
Shielding Angles:
90
90
Plane:
0-Deg
90-Deg
Luminous Length:
48.000
9.000
Height of Side:
3.960
3.960
0.0
45.0
90.0
FLUX
0
2847
2847
2847
5
2820
2805
2811
266
15
2644
2579
2561
731
25
2318
2220
2059
1013
35
1937
1730
2164
1197
45
1510
1594
2211
1330
55
1039
1394
2011
1274
65
548
1033
1319
935
75
247
454
758
502
85
65
168
90
150
90
6
112
19
95
22
66
23
52
105
43
58
26
65
115
52
179
112
128
125
55
259
258
185
135
57
259
329
174
145
59
192
296
116
155
60
127
186
58
165
64
73
92
22
175
61
50
48
5
180
53
53
53
CANDELA DISTRIBUTION
0
AVERAGE AVERAGE AVERAGE AVERAGE
IN DEG.
0-DEG.
45-DEG.
90-DEG.
45
7075.
6411.
7788.
55
5812.
6348.
7722.
65
3952.
5619.
5760.
75
2617.
3186.
3976.
85
1377.
1734.
614.
LUMINANCE DATA IN CANDELA/SQ. METER
COEFFICIENTS OF UTILIZATION –
ZONAL CAVITY METHOD. EFFECTIVE 
FLOOR CAVITY REFLECTANCE 0.20
0
RC
80
50
30
RW 70 50 30 50 30 10 50 30 10
0
1 99 95 91 86 83 81 81 79 77
0
2 90 83 76 75 70 66 71 67 64
0
3 82 72 65 66 60 55 62 57 53
0
4 75 64 56 59 52 47 55 50 46
0
5 69 57 49 52 46 41 50 44 39
0
6 64 51 43 47 41 36 45 39 35
0
7 59 46 38 43 36 31 41 35 31
0
8 55 42 35 39 33 28 37 32 27
0
9 51 39 31 36 30 25 35 29 25
10 48 36 29 33 27 23 32 26 22
ZONE
LUMENS % LAMP
% FIXT
0
0-
0
30
2010
22.8
24.5
0
0-
0
40
3207
36.4
39.0
0
0-
0
60
5810
66.0
70.7
0
0-
0
90
7398
84.1
90.1
90-120
256
2.9
3.1
90-130
441
5.0
5.4
90-150
731
8.3
8.9
90-180
816
9.3
9.9
0
0-180
8214
93.3
100.0
ZONAL LUMEN SUMMARY
Lightolier 
a Genlyte company
www.lightolier.com
Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 a Genlyte company
Section 5/Folio K60-15
Voltage:
120, 277 or
UNV=120-277
14= 14 Cell
Louver
1 Row
28= 28 Cell
Louver
2 Rows
F
Finish:
F= Flat
White
2
Lamp
Quantity:
2=2 Lamp
2 Lamps in
Tandem
for 96" Units
Ballast Type:
<
20THD
<
10THD
1-2 or 2-2 Lamp Elec. T8
SO *
H
I *
1-4 Lamp Elec. T8
O4 *
H4 *
1-2 or 2-2 Lamp 28W Elec. T5
P
I †
1-2 or 2-2 Lamp 28W or 54W Elec. T5
PG ††
1-4 Lamp 54W Elec. T5
PV ††
LOL T8 Dimming
PS 
*
Other dimming options. Consult factory.
*Instant Start Standard
†Instant Start (120V or 277V only)
††Program Rapid Start (UNV only)
NOTE: 
For T8 UNV, you must use HI, H4 Ballast Code.