Franke Consumer Products FQD 907 사용자 설명서

다운로드
페이지 52
 
 
 
 
EN 
 
2
3
 
23 
Comfort panels 
•  Open the comfort panels. 
•  To unfasten the side panels from the hood casing it is necessa-
ry to slide the fixing pivot lever. 
•  When unfastening the central comfort panel pull it forcefully 
using both hands. 
•  It is recommended to use a neutral detergent liquid and a damp 
cloth when washing the outer surface of the comfort panel.  
•  Wash the inner part of the panel as well by using a neutral de-
tergent liquid and a damp cloth; in any case do not use wet 
sponges or other clothes nor water jet or corrosive detergents.
 
 
 
Charcoal filter (recycling version) 
•  This filter cannot be washed or regenerated. It must be replaced when the EF appears on the 
display or at least once every 4 months.  
Activation of the alarm signal  
•  In the recycling version hoods the filter saturation alarm must be activated during the instal-
lation or later. 
•  Switch off the hood and the lights. 
•  Disconnect the hood from the mains supply. 
•  When restoring the connection press and hold B-key. 
•  When releasing the key two rotating rectangles appear on the display. 
•  Within 3 seconds press the B-key until a flashing confirmation appears on the dispaly: 
  •  2 flashes with EF - charcoal filter saturation alarm ACTIVATED 
  •  1 flash with EF - charcoal filter saturation alarm DEACTIVATED.  
 
REPLACING THE CHARCOAL FILTER 
Reset of the alarm signal 
•  Switch off the hood and the lighting. If the 24h-function has 
been activated this has to be deactivated. 
•  Press the E-key until the display is unlit. 
Replacing of the filter  
•  Open the comfort panels pulling them downwards. 
•  Remove the metal grease filters. 
•  Remove the saturated charcoal filter by releasing the fixing 
hooks 
•  Fit the new filter and fasten it in its correct position. 
•  Put the metal grease filters in their seats. 
•  Close the comfort panels.  
 
A
B