Canon GC-251 사용자 설명서

다운로드
페이지 88
 
CANON    Digital Galvano Scanner System
 
KP-1SM Series + GC-251 
Users Manual 1.00 
 
 
 
  
35
RS-232C command 
 
Send Command ID14 “Status read” and check the following: 
 
SRVON, SYNC, INPOS = High 
ORGN = Low 
 
(For details, see 7-2, “Command Details.”)