Operations Commands
Operations commands allow more flexible and direct control of the projector. The syntax
for operations commands is as follows:
for operations commands is as follows:
op <operation> <command>[CR]
(Precede
<operation> and <command> with a space.)
The command type can be one of 5 functions:
Table 6-2 lists the valid operations commands. For all but Execute functions, the response
from the projector is the command and “= <value>” where <value> is the current value or
“NA” if the value is not available. For Execute functions the response is the same
command. All responses are in UPPERCASE.
from the projector is the command and “= <value>” where <value> is the current value or
“NA” if the value is not available. For Execute functions the response is the same
command. All responses are in UPPERCASE.
Some operations command examples:
Input:
op bright ? [CR]
Response:
OP BRIGHT = 100 [CR]
Input:
op bright + [CR]
Response:
OP BRIGHT = 101 [CR]
Input:
op bright = 127 [CR]
Response:
OP BRIGHT = 127 [CR]
Input:
op bright - [CR]
Response:
OP BRIGHT = 126 [CR]
Input:
op resync [CR]
Response:
OP RESYNC [CR]
0x10
(none)
The projector does not respond to this key.
0x13
(none)
The projector does not respond to this key.
(none)
(none)
Activates remote backlighting when pressed.
Table 6-1. Serial Command Key Names and IR Codes (continued)
IR Code
RS232
Keyname
Remote Button
Description
ZOOM
LENS
LIGHT
➤
Operations Control Commands
Function
Command
Description
Set
= <value>
Assigns that value to the parameter.
Get
?
Returns the current value of that parameter.
Increment
+
Adds 1 to the current value.
Decrement
-
Subtracts 1 from the current value.
Execute
(none)