Model IFT9701 Transmitter Instruction Manual
IFT9701 Specifications
 continued
A.3.3
Humidity limits
5 to 95% non-condensing
A.3.4
Vibration limits
Meets IEC 68.2.6, 2 g, endurance sweep, 10 to 2000 Hz, 50 sweep cycles
A.4
Density limits
0.2 to 2.0 g/cc (200 to 2000 kg/m
3
) for volume flow
0.0 to 2.0 g/cc (0 to 2000 kg/m
3
) for mass flow
150
100
130
80
110
140
90
120
70
158 167 176 185 194 203 212 221 230 239 248 257 266
Maximum, with no
external heat source
Process fluid temperature, °F
Expe
cted
 maximum
a
m
bien
t temperature
, °F
Maximum, when mounted
in direct sunlight
30
70
75
80
85
90
95
100 105 110 115 120 125 130
35
40
45
50
55
60
Process fluid temperature, °C
Expected m
a
xim
u
m
a
m
bien
t temperature
, °C
Maximum, with no
external heat source
Maximum, when mounted
in direct sunlight