Menu Item
Description
installed in the specified slot. Slot disablement must be used only when 
the installed peripheral card is preventing booting into the operating 
system or causing delays in system startup. If the slot is disabled, both the 
Option ROM and UEFI driver are disabled.
Serial Communication screen
You can use the Serial Communication screen to view the properties of the serial communication port.
To view the Serial Communication click System Setup Main Menu → System BIOS → Serial 
Communication.
Menu Item
Description
Serial Communication 
Selects serial communication devices (Serial Device 1 and Serial Device 2) 
in the BIOS. BIOS console redirection can also be enabled and the port 
address can be specified. By default, Serial Communication option is set 
to Auto.
Serial Port Address 
Enables you to set the port address for serial devices. By default, the 
Serial Port Address option is set to Serial Device 1=COM2, Serial Device 
2=COM1
NOTE: You can use only Serial Device 2 for the Serial Over LAN 
(SOL) feature. To use console redirection by SOL, configure the 
same port address for console redirection and the serial device.
NOTE: Every time the system boots, the BIOS syncs the serial MUX 
setting saved in iDRAC. The serial MUX setting can independently be 
changed in iDRAC. Therefore, loading the BIOS default settings from 
within the BIOS setup utility may not always revert this setting to the 
default setting of Serial Device 1.
External Serial Connector
You can associate the External Serial Connector to Serial Device 1, Serial 
Device 2, or the Remote Access Device using this field.
NOTE: Only Serial Device 2 can be used for (Serial Over LAN) SOL. 
To use console redirection by SOL, configure the same port address 
for console redirection and the serial device.
NOTE: Every time the system boots, the BIOS syncs the serial MUX 
setting saved in iDRAC. The serial MUX setting can independently be 
changed in iDRAC. Therefore, loading the BIOS default settings from 
within the BIOS setup utility may not always revert this setting to the 
default setting of Serial Device 1.
Failsafe Baud Rate
Displays the failsafe baud rate for console redirection. The BIOS attempts 
to determine the baud rate automatically. This failsafe baud rate is used 
only if the attempt fails, and the value must not be changed. By default, 
the Failsafe Baud Rate option is set to 115200.
Remote Terminal Type
Sets the remote console terminal type. By default, the Remote Terminal 
Type option is set to VT 100/VT 220.
Redirection After Boot 
Enables or disables the BIOS console redirection when the operating 
system is loaded. By default, the Redirection After Boot option is set to 
Enabled.