LEAKAGE CHECKPOINTS
Read this manual fi rst.  Then before checking the water heater make 
sure the gas supply has been turned “OFF”, and never turn the gas 
“ON” before the tank is completely full of water.
Never use this water heater unless it is completely fi lled with water.  
To prevent damage to the tank, the tank must be fi lled with water.  
Water must fl ow from the hot water faucet before turning “ON” gas 
to the water heater.
A.  Water at the blower assembly is water vapor which has condensed 
out of the combustion products.  This is caused by a problem in 
the vent.  Contact the gas utility.
B.  *Condensation may be seen on pipes in humid weather or pipe 
connections may be leaking.
C.  *The anode rod fi tting may be leaking (anode is located under the 
Blower Assembly).
D.  Small amounts of water from temperature-pressure relief valve 
may be due to thermal expansion or high water pressure in your 
area.
E.  *The temperature-pressure relief valve may be leaking at the tank 
fi tting.
F.  Water from a drain valve may be due to the valve being slightly 
opened.
G.  *The drain valve may be leaking at the tank fi tting.
H.  Combustion products contain water vapor which can condense on 
the cooler surfaces of the tank.  Droplets form and drip onto the 
burner or run on the fl oor.  This is common at the time of start-up 
after installation and when incoming water is cold.
I.   Water in the water heater bottom or on the fl oor may be from 
condensation, loose connections, or the relief valve.  DO NOT 
replace the water heater until a full inspection of all possible water 
sources is made and necessary corrective steps taken.
Leakage from other appliances, water lines, or ground seepage should 
also be checked.
*  To check where threaded portion enters tank, insert cotton swab 
between jacket opening and fi tting.  If cotton is wet, follow “Draining” 
instructions in the “Periodic Maintenance” section and then remove 
fi tting.  Put pipe dope or tefl on tape on the threads and replace.  
Then follow “Filling the Water Heater” instructions in the “Installing 
the New Water Heater” section.
8.  Follow the lighting instructions in the “Lighting” section to restart 
the water heater.
FIGURE  23.
SERVICE
If a condition persists or you are uncertain about the operation of the 
water heater contact a service agency.
Use this guide to check a “Leaking” water heater.  Many suspected 
“Leakers” are not leaking tanks.  Often the source of the water can 
be found and corrected.
If you are not thoroughly familiar with gas codes, your water heater, 
and safety practices, contact your gas supplier or qualifi ed installer 
to check the water heater.