Rinnai V53E 사용자 설명서

다운로드
페이지 64
 
18 
V53i & V53e Operation and Installation Manual 
  Clearances 
from 
Appliance     
                   
1.  Identify the installation location and confirm that 
the installation will meet all required clearances. 
2.  Securely attach the water heater to the wall using 
any of the holes in the wall installation brackets 
which are at the top and bottom of the water 
heater.  Ensure that the attachment strength is 
sufficient to support the weight.   Refer to the 
weight of the water heater in the Specifications 
section. 
NOTE: Rinnai water heaters should be installed in an 
upright position.  Do not install upside down or on it 
side. 
  Attachment of the Water Heater   
 
                       
wall installation 
brackets 
 
to 
Combustibles  
 
to Non-
Combustibles   
Top of 
Heater 
6 inches *
(152 mm) 
2 inches *
(51 mm) 
Back of 
Heater 
0 (zero) 
0 (zero) 
Front of 
Heater 
6 inches 
(152 mm) 
6 inches 
(152 mm) 
Sides of 
Heater 
2 inches 
(51 mm) 
1/2 inch 
(13 mm) 
Ground/
Bottom 
12 inches 
(305 mm) 
12 inches 
(305 mm) 
Vent 
0 (zero) 
0 (zero) 
The clearance for servicing is 24 inches in front of the water heater. 
For closet installation:  clearance is 6 inches (152 mm) from the front. 
 
* 0 inches from vent components and condensate drain line. 
to side
to front
to top
to ground/bottom
 
to 
Combustibles  
 
to Non-
Combustibles 
 
Top of 
Heater 
12 inches 
(305 mm) 
2 inches 
(51 mm) 
Back of 
Heater 
0 (zero) 
0 (zero) 
Front 
(Panel) 
24 inches 
(610 mm) 
0 (zero) 
Sides of 
Heater 
6 inches 
(152 mm) 
1/8 inch 
(3.2 mm) 
Floor/
Ground 
12 inches 
(305 mm) 
2 inches 
(51 mm) 
Front 
(Exhaust) 
24 inches 
(610 mm) 
24 inches 
(610 mm) 
V53i V53e