1.  Turn  “OFF”  the  electric  power  to  the  water  heater  at  the 
junction box.
2.  Take off the access panel and remove the insulation cap with 
handle.
3.  The slotted adjustment (using a screwdriver) can be turned 
clockwise ( 
 ) to increase the temperature setting or 
counter  clockwise  ( 
  )  to  decrease  the  temperature 
setting.
4.  Replace  the  insulation  cap  with  handle  and  access 
panel.
5.  Turn “ON” the power supply.
Temperature-Pressure Relief 
Valve Operation
The temperature-pressure relief valve must be manually operated 
at least once a year.
The  temperature-pressure  relief  valve  must  be  manually 
operated  at  least  once  a  year.  Caution  should  be  taken  to 
ensure that (1) no one is in front of or around the outlet of the 
temperature-pressure relief valve discharge line, and (2) the 
water manually discharged will not cause any property damage 
or bodily injury. The water may be extremely hot.
FIGURE 14.
If after manually operating the valve, it fails to completely reset 
and continues to release water, immediately close the cold water 
inlet to the water heater, follow the draining instructions, and 
replace the temperature-pressure relief valve with a new one.
Failure to install and maintain a new properly listed temperature-
pressure relief valve will release the manufacturer from any claim 
which might result from excessive temperature or pressure.
If the temperature-pressure relief valve on the appliance weeps 
or discharges periodically, this may be due to thermal expansion. 
Your water heater may have a check valve installed in the water 
line  or  a  water  meter  with  a  check  valve.  Consult  your  local 
Sears Service Center for further information. Do not plug the 
temperature-pressure relief valve.
Draining
The water heater should be drained if being shut down during 
freezing temperatures. Also, periodic draining and cleaning of 
sediment from the tank may be necessary.
1.  Before beginning turn “OFF” the electric power supply to the 
water heater.
2.  CLOSE the cold water inlet valve to the water heater.
3.  OPEN a nearby hot water faucet and leave open to allow for 
draining.
4.  Connect  a  hose  to  the  drain  valve  and  terminate  to  an 
adequate drain or outdoors.
5.  OPEN  the  water  heater  drain  valve  to  allow  for  tank 
draining.
NOTE:  If  the  water  heater  is  going  to  be  shut  down  and  
drained for an extended period, the drain valve should be 
left open with hose connected allowing water to terminate 
to an adequate drain.
6.  Close the drain valve.
7.  Follow “Filling the Water Heater” instructions in the “Installation 
Instructions” section.
8.  Turn “ON” power to the water heater.
Never use this water heater unless it is completely full of water. 
To prevent damage to the tank and heating element, the tank 
must be filled with water. Water must flow from the hot water 
faucet before turning “ON” power.