Kenmore 153.31604 사용자 설명서

다운로드
페이지 24
5
PRODUCT SPECIFICATIONS
 
 
 
                             
 
               
   
                
            
 
                
 
 
 
 
               
                               
 
  
 
 
MAXIMUM FUSE 
 
 
 
 
 
 RECOVERY RATE 
 
 
MINIMUM 
OR CIRCUIT
 
MODEL 
  IN GALLONS                   
  
GALS.PER HOUR 
 
 
WIRE SIZE* 
BREAKER
 
NUMBER 
(LITERS) 
DIA. 
HEIGHT 
@90
0
F Rise 
120 Volt  240 Volt 
(GAUGE) 
SIZE (AMPS)
 
153.316040 
6 (22.7) 
14.250” (362) 15.375” (391) 
7.5 
1650 
---- 
12 
20
 
153.316050 
10 (37.8) 
16” (406)  18.25” (464) 
7.5 
1650 
---- 
12 
20
 
153.316060 
19 (71.9) 
18” (457) 
24.9” (632) 
7.5 
1650 
---- 
12 
20
 
153.316070 
19.9 (75.3) 
16” (406)  31.62” (803) 
7.5 
1650 
---- 
12 
20
 
153.316331 
30 (113.6) 
22” (559) 
30” (762) 
7.5 
1650 
---- 
12 
20
 
153.326060 
19 (71.9) 
18” (457) 
24.9” (632) 
9.1 
---- 
2000 
14 
15
 
153.326070 
19.9 (75.3) 
16” (406)  31.62” (803) 
9.1 
---- 
2000 
14 
15
 
153.326331 
30 (113.6) 
22” (559) 
30” (762) 
9.1 
---- 
2000 
14 
15
 
* Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.
Some compact models have labeled optional plumbing connections see below.
MODEL
NUMBER
STANDARD
SIDE COLD INLET
STANDARD
SIDE HOT INLET
STANDARD
SIDE T&P
MODEL HAS OPTIONAL 
TOP COLD INLET
MODEL HAS OPTIONAL
TOP HOT OUTLET OR T&P
5.600
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
5.6050
YES
YES
YES
NO
YES, PLUGGED
5.6060
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
5.6070
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
5.6
YES
YES
YES
NO
NO
153.326060
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
153.326070
YES
YES
YES
YES, PLUGGED
YES, PLUGGED
153.326331
YES
YES
YES
NO
NO
DIMENSIONS
      IN INCHES (mm)         
TANK
CAPACITY 
ELEMENT
WATTAGE
HEATER REQUIRES ABILITY EQUIVALENT TO THAT OF 
A  LICENSED  TRADESMAN  IN  THE  FIELD  INVOLVED. 
PLUMBING AND ELECTRICAL WORK ARE REQUIRED.
  Examine the location to ensure the water heater complies with the 
“Facts to Consider About the Location” section in this manual.
5.  For California installation this water heater must be braced, 
anchored, or strapped to avoid falling or moving during 
an  earthquake.  See  instructions  for  correct  installation 
procedures. Instructions may be obtained from California 
Office of the State Architect, 400 P Street, Sacramento, 
CA 95814.
6.  Massachusetts  Code  requires  this  water  heater  to  be 
installed  in  accordance  with  Massachusetts  248-CMR 
2.00: State Plumbing Code and 248-CMR 5.00.