Lochinvar ARM3072PAB 전단

다운로드
페이지 1
 
 
 
 
PUMP-Rec-12 Rev B 
PUMP 
Recommendation 
 
PUMP RECOMMENDATION FOR 
INTELLI-FIN 1500-2000 WATER HEATER 
 
Pump Specifications 
Part No. 
HorsePower 
Flanges 
Valute Material 
Flange Material 
Vendor 
Vendor Product Series 
Orientation 
ARM3072PAB 3/4  2-1/2"  Bronze 
Bronze 
Armstrong 
2B1060 
 
Vertical 
 
Installation Specifications 
  
Recommended for 
 
Based on 
      Pump 
Model Numbers 
Maximum GPM 
Installation Type 
  
Intelli-fin Wtr Htr, IW(N,L) 1500-2000 
90 GPM 
Single Water Heater piped to a Single Storage Tank 
ARM3072PAB 
Based on 
Based on 
  
  
Minimum Pipe Diameter 
Connecting piping 
  
  
2-1/2" 
Maximum 45 feet straight pipe with 6-Elbows, 2-Unions, 2-Ball Valves and 1-Cold Water Inlet Tee 
IMPORTANT: Read the Intelli-fin 1500-2000 Installation and Operation Manual.  If the planned system exceeds 
the pump capacity in flow and/or head see “Pump Curves-All Pumps” for alternate pumps and pump curves. 
 
 
OIL PORT
A
C
16” 
19-1/2” 
 
 
 
 
(See ¾ HP Curve) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
B
D
11-1/2”