Honeywell TZ-4 사용자 설명서

다운로드
페이지 20
TZ-4 TOTALZONE® ZONE CONTROL PANEL
68-0259-1
4
INSTALLATION
Mounting
CAUTION
Equipment Damage Hazard. 
Do not mount TZ-4 inside HVAC equipment
Mount only on wall or on cold air return.
Identifying DIP Switches
This panel has two banks of DIP switches, DIP switch 4 (S4) 
and DIP switch 5 (S5), see Fig 15. Each bank has eight 
individual switches that are identified by two numbers; the first 
number is the bank number (4 or 5) and the second number 
identifies the individual switch. For example, DIP 5-1 is bank 
5, switch 1.
1. Mount the thermostats in each zone of the living space 
using the installation instructions provided with each 
thermostat.
2. Mount the dampers in the ductwork using the installa-
tion instructions provided with each damper.
3. Mount the TZ-4 zone panel near the HVAC equipment; 
(on a wall or on the cold-air return). See Fig. 2.
4. Level the TZ-4 for appearance only.
Wiring
CAUTION
Voltage Hazard. 
Can cause electrical shock or equipment damage.
Disconnect power before continuing installation.
Wiring must comply with applicable codes, ordinances, and 
regulations.
1. Connect thermostats as shown in Fig. 3-6. 
2. Connect dampers as shown in Fig. 7-10.
3. Connect C7735A Discharge Air Temperature Sensor 
(not supplied) to the DATS terminals. The wires are not 
polarized. See Fig. 13.
4. Connect Add-A-Zone panels (if used) to the AZ1 and 
AZ2 terminals. 
5. Connect the HVAC equipment to the EQUIP terminals 
on the panel. See Fig. 15-21.
6. Connect a 40 VA, 24 volt transformer to R (hot) and C 
(common). This must be a dedicated transformer and 
each TAZ-4 board also requires a transformer. See Fig. 
12.
7. The auxiliary 40 VA 24-volt transformer can be con-
nected to T1 and T2 if additional power for dampers is 
required. This second transformer is not required; how-
ever, total power consumption of panel and damper is 
limited to 40VA without it.
Fig. 2. TZ-4 mounting location.
Table 3. Required Accessories (Not Supplied).
Accessory
Description
Bypass Rating
(cfm)
40 VA 
transformers 
AT140D1046 
(PMT-40)
Capacity 
protector
C7735A1000
Outdoor 
Temperature 
Sensor
(Required for 
dual-fuel 
applications)
C7089B1000
Round static 
pressure 
regulator 
damper
SPRD7
SPRD8
SPRD9
SPRD10
SPRD12
SPRD14
SPRD16
300 
400 
600 
750 
1200 
1800 
2400 
Rectangular 
static pressure 
regulator 
damper
SPRD12x8
SPRD12x10
SPRD12x12
SPRD20x8
SPRD20x10
SPRD20x12
1000 
1200 
1400 
1600 
2000 
3000 
M20517
WATER 
HEATER
TZ-4
EL
EC
TR
ON
IC A
IR C
LE
AN
ER
RETURN
AIR
TZ-4
OPTIONAL
LOCATION
FURNACE 
OR BOILER
HIGH
 EFFICIENCY
AIR CLEANER