SYMPTOM
POTENTIAL SOLUTION
Thermostat will not
allow me to program
a setpoint
temperature lower
than 45˚ F (7˚ C).
This is below the normal thermostat temperature setting range
of 45˚ to 90˚ F (7˚ to 32˚ C).
Fan continues to run
all the time whether
the system is on or
off.
Check that the fan control switch is in the AUTO position. This
will allow the fan to run only when the heating or cooling system
is turned on and running.
Check thermostat wiring to make sure that the fan control
wiring is connected to the correct terminals on the wiring
terminal block. See Installation and Wiring Diagrams sections of
this manual.
Fan continues to run
in cooling mode when
the system has
turned off.
The Residual Cooling Fan Control Feature can allow up to a 90
second fan delay after cooling system shutdown for energy
efficiency gains. The default setting is 60 seconds. This can be
changed to disable this feature or shorten the time period if
desired. See Setting Residual Cooling Fan Feature section of
this manual.
The room is too
warm or too cold.
See Review Set Temperature section of this manual to verify the
current setpoint and make any modifications that are necessary.
LO is shown in the
thermostat display
where the room
temperature is
normally displayed.
The temperature sensed by the thermostat is lower than the 40˚
F (5˚ C) lower limit of the thermostats display range. The display
will return to normal after the sensed temperature rises within
the 40˚ to 99˚ F (5˚ to 37˚ C) display range. If the temperature in
the controlled space seems to be normal, wait for the
thermostat to acclimate to the correct room temperature. If the
room seems to be colder than usual, turn on the heating system
to raise the temperature as needed for comfort within the room.
This condition could occur from the system being turned off
during a cold weather period or upon installation when the
thermostat has been stored for a long period of time in a cold
vehicle or location prior to being installed. The thermostat
should be allowed to warm up prior to installation to allow
proper heating control once installed.
TROUBLESHOOTING
7
cont.
17
Typical
Carrier, Bryant, Payne, Day & Night and Reliant
Heat Pumps
WIRING DIAGRAMS
8
THERMOSTAT TERMINAL BLOCK
HE
AT
PU
M
P
PC
B
R
R
Y
W2
E
G
O
L
or
X
C
Y1
Y2
W2
E
G
O
B
L
C
Typical
Comfortmaker and Heil-Quaker
Heat Pumps
THERMOSTAT TERMINAL BLOCK
HE
AT
PU
M
P
PC
B
R
CAPPED
CAPPED
R
Y
W1
G
O
C
W2
X
Y1
Y2
W2
E
G
O
B
L
C
Typical
Coleman, Rheem and Ruud
Heat Pumps
THERMOSTAT TERMINAL BLOCK
HE
AT
PU
M
P
PC
B
R
R
Y
W2
E
G
B
L
X
Y1
Y2
W2
E
G
O
B
L
C
User
Supplied
Jumper