SCALDING HAZARD.  If the water temperature is 
over 120°F, household members can suffer serious 
or  fatal  scalding  and  painful  and  permanent  injury.  •  The  Consumer
Products Safety Commission recommends an initial setting of 120°F, but 
advised that a slower response time of infants, aged, disabled and other 
persons increases the scalding hazard and may require lower settings. •
Always check the water temperature before use, including washing, 
bathing or showering. • Temperature limiting valves are available from your
plumbing supplier. A check valve must be installed in the boiler return line 
to prevent gravity flow through the heat exchanger. This can cause 
overheating and result in serious or fatal scalding.
SCALDING HAZARD.  If the thermostat is not 
working properly or if this product is not installed in 
accordance with the manual, water temperature can reach excessive levels 
that may cause serious or fatal scalding. After installation and any servicing 
of the unit, verify that the thermostat is working and firmly inserted in the 
thermostat well by following the thermostat testing instructions in 
 
the manual.
Failure to use the correct replacement parts may 
make your product unsafe.
In limited circumstances, space heating can be lost in 
the home with unit utilizing priority mode.  Any 
demand for space heating is postponed until the water heater  has reached 
its set temperature.  This delay in supplying the space heating zones is 
usually not noticed by the inhabitants of the living spaces.  However, in the 
event of certain malfunctions such as circulator or thermostat failure, space 
heating could be delayed indefinitely.  If undetected and uncorrected, 
freezing damage to piping could result. 
If a steel hydropneumatic tank is in place, replace it 
with a properly sized diaphragm expansion tank. 
Otherwise, significant heat transfer problems can occur by causing air to be 
trapped in the heat exchanger. If the boiler system has a diaphragm 
expansion tank and the boiler temperatures are being changed, resize the 
expansion tank.
If installing on city water supply, a properly sized 
thermal expansion tank is required with the water 
heater and should be installed as set fo rth in the product installation 
manual. Contact your water supplier or local plumbing inspector for 
additional information.
Prevent pressure build-up in any existing internal 
tankless coil.  Do not plug incoming or outgoing 
tappings in the internal tankless coil plate.  Leave the coil in the boiler and 
leave system connections open to prevent pressure build-up.
Electrocution hazard.  The water heater must be 
electrically grounded. Electrical supply must come 
from the boiler side of boiler’s emergency shut-off switch in order to prevent 
unsafe boiler operation.
Chlorine Aggressive Water: The water quality can 
significantly influence the life of this Product.  You 
should test for corrosive elements, acidity, total solids and other relevant 
contaminants, including chlorine and treat your water appropriately to 
insure satisfactory performance and prevent premature failure.
Note:  Inspect for shipping damage and notify freight carrier or store where 
purchased immediately if damage is present.  To avoid risk of personal 
injury and property damage, if the product appears to be malfunctioning or 
shows signs of corrosion, call a qualified professional immediately.  Current 
copies of the Product Manual can be obtained at the place of purchase.  
Use proper safety equipment when installing.
EXPLOSION HAZARD.  The pressure of the heat 
transfer medium must be limited to a maximum of 30 
psig by an approved safety or relief valve on your boiler.  The water heater 
pressure must be limited to 150 psig maximum by the installation of a 
temperature and pressure relief valve (included). The relief tube must be 
plumbed to a suitable drain per code. No reducing coupling or other 
restriction may be placed in this line.
This Product, like most Products under pressure, 
may over time corrode, weaken and burst or explode, 
causing serious or fatal injury, leaking or flooding and/or property damage.  
To minimize risk, a licensed professional must install and periodically 
inspect and service the Product.  A drip pan connected to an adequate 
drain must be installed if leaking or flooding could cause property damage.  
Do not locate in an area where leaking could cause property damage to the 
area adjacent to the appliance or to lower floors of the structure.
EXPLOSION OR RUPTURE HAZARD. A relief valve 
must be installed to prevent pressure in excess of 
local code requirement or maximum working pressure designated in the 
Product Manual, whichever is less.  Do not expose Product to freezing 
temperatures or temperatures in excess of the maximum rated 
 
operating temperature.
If not installed by the boiler manufacturer, install a 
low water cut-off or pressure reducing valve on your 
boiler so that leaking will not result in a dry boiler which if the boiler 
continues to fire, will cause an explosion hazard.
This unit must be installed as a separate heating 
zone.  Do not connect this unit to an existing heating 
zone or feed boiler water directly through the coil as dangerous over-heating 
will result.
Do not drain this appliance before shutting off the 
supply valve and opening the relief valve or another 
downstream fixture, as it will damage this unit.  A vacuum breaker should 
be installed to avoid damaging the liner. Damage to the unit and leakage 
can occur if a vacuum breaker is not installed.
USE GLYCOL ONLY WITH DOUBLE-WALLED 
HEAT EXCHANGER MODELS.  Avoid risk of 
ingesting a toxic glycol fluid. The heat transfer medium should be water. If 
glycol must be used, it should only be used with double-walled heat 
exchangers and closely monitored for leakage.
CALIFORNIA PROPOSITION 65 WARNING! This 
product contains a chemical known by the State of 
California to cause cancer and to cause birth defects or other reproductive 
harm. (California Installer/Contractor - California law requires that this 
notice be given to consumer/end user of this product.) For more information:  
www.amtrol.com/prop65.htm
As in all plumbing products and water storage 
vessels, bacteria can grow in this Product, especially 
during times of non-use.  Consult your local plumbing professional 
regarding any steps you may wish to take to safely disinfect your home’s 
plumbing system.
EXPLOSION OR RUPTURE HAZARD!  A relief 
valve must be installed to prevent pressure in excess 
of local code requirement or maximum working pressure designated in the 
Product Manual, whichever is less.  At least once every 3 years or if 
discharge is present, a licensed contractor should inspect the temperature 
and pressure relief valve and replace if corrosion is evident or the valve 
does not function.  
FAILURE TO INSPECT THIS VALVE AS DIRECTED 
COULD RESULT IN UNSAFE TEMPERATURE OR PRESSURE 
BUILD-UP WHICH CAN RESULT IN PRODUCT FAILURE, SERIOUS 
INJURY OR DEATH AND/OR SEVERE PROPERTY DAMAGE AND 
VOID THE PRODUCT WARRANTY.