The installer may be able to observe and correct certain problems 
which may arise when the unit is put into operation. HOWeVer, 
it  is  recommended  that  only  a  qualified  service  agency,  using 
appropriate test equipment, be allowed to service the heater.
As  preliminary  step,  check  wiring  against  diagram,  check  for 
grounded, broken or loose wires.  Check all wire ends to be sure 
that they are making good contact.
ignition Control system
before  calling  your  qualified  service  agency,  the  following 
checklist  should  be  examined  to  eliminate  obvious  problems 
from those requiring replacement or servicing.
•  Check that “main gas shutoff valve” is fully open and that gas 
service has not been interrupted.
•  Check  electrical  supply  to  the  appliance  for  possible  blown 
(or tripped) fusing or power interruption. Also check the 3 amp 
fuse on the front of the digital thermostat (Fig. 2).
•  Is  the  water  temperature  in  tank  below  the  thermostat  dial 
setting on the appliance thermostat (calling for heat)?
•  It is possible that the high limit (e.C.O.) has functioned to shut 
off  the  appliance.  See  page  7  -  High  limit  Switch  for  reset 
procedure.  Contact  your  service  agent  if  limit  continues  to 
function to shut off appliance. 
and pour the Un•lIMe into the heater.
7.  lower container, you may have to place the container on 
its empty carton to prevent the Un•lIMe from flowing back 
into the container.
8.  let Un•lIMe remain in the heater for 5 minutes and then 
lower the container to the “Drain” Position, see Figure 27.
9.  Deliming activity is indicated by foaming on the surface of the 
Un•lIMe. If there is deliming activity, repeat steps 6 thru 8.
normally, lime removal will be completed within one hour.  Severe 
build-up of lime may take longer than an hour to complete descaling.
note: To check Un•lIMe for continued use, place some scale 
or white chalk in a glass with a small amount of Un•lIMe.  If 
the material is vigorously dissolved by the Un•lIMe, it can be 
reused; if not, the Un•lIMe should be replaced.
figure 27.
9.  Install  the  long  plastic  male  adapter  insert  fitting  into  the 
drain valve opening of heater after applying Teflon tape or 
paste to threads. Tighten firmly by hand and use wrench or 
adjustable pliers to check for secure connection. Do not over 
tighten to avoid damage to threads and fittings.
Prepare the Up-n-Down Transfer Kit
The next step is the preparation on the Up-n-Down Transfer Kit, 
if you have not already done so:
1.  With  the  5  gallon  Up-n-Down  container  in  the  vertical 
position,  unscrew  the  plastic  vent  cap  in  the  handle  and 
pierce the plastic membrane over the vent boss under the 
cap to allow the container to vent.
note:  If  your  container  does  not  have  the  vent  cap  and 
vent boss, drill a 3/16” hole in the handle.  When you have 
finished deliming you will be able to plug this drilled vent with 
the stainless steel screw that is supplied with the kit.
2.  remove the container’s cap and cut the plastic membrane 
located in the 3/4” IPT opening in the cap.  Take care to not 
damage the threads.
3.  Find the 3/4” male adapter, apply teflon tape to the threaded 
end and screw it into the 3/4” IPT opening in the cap.
4.  Put cap with male adapter back on the container and slide  
3/4” hose over end of male adapter and fasten in place using 
hose clamp provided.
Delime using Flo-Jug Method
5.  Slide the hose clamp over end of hose and slide hose over 
the  male  adapter  in  the  water  heater  drain  opening  and 
secure in place using hose clamp.
6.  lift container to the “Pour” Position, see Figure 27, being 
careful to keep the vent in the handle above the liquid level 
serViCe
system diagnostiCs
Your  water  heater  is  equipped  with  an  ignition  control  that 
incorporates  a  diagnostic  system  to  assist  in  troubleshooting 
the  appliance. The  indicator  codes  on  the  ignition  module  are 
as follows:
taBle 9.
2 FlASHeS Flame sensed without call for heat
3 FlASHeS Ignition lockout
Steady On
Internal control failure
If  an  internal  control  failure  is  indicated,  replace  the  ignition 
control.
Use  this  diagnostic  system  in  conjunction  with 
“TrOUbleSHOOTInG” and the “SeqUenCe OF OPerATIOn” 
to troubleshoot the appliance.
eleCtriCal serViCing
lAbel  All  WIreS  PrIOr  TO  DISCOnneCTIOn  WHen 
SerVICInG  COnTrOlS.  WIrInG  errOrS  CAn  CAUSe 
IMPrOPer AnD DAnGerOUS OPerATIOn.
VerIFY PrOPer OPerATIOn AFTer  SerVICInG.