Servicing should only be performed by a Qualifi ed Service Agent
TROUBLESHOOTING
TEST 7: BLOWER ON, BLOWER PROVER SWITCH CLOSED, NO IGNITER 
OPERATION
Conditions:
Power on, but no power to igniter
• 
Plugs in receptacles
• 
Blower (Draft Inducer) on
• 
24V at ignition board E1, Pin 10
• 
1
2
3
4
E4 Plug
Continuity
Test
Check E1 pin 10 - 24V
Check E4 pin 4 to Ground
Ground
Ground
Check E4 pin 2 to Ground
Figure 26
TEST 7
Voltage check and continuity check of hot surface igniter circuit
Continuity check - Power off- Plug removed from E4 receptacles.  
Nominal 80 VAC check - Plug in E4- Power on.
IF.........
then............
Continuity is not indicated between E4 plug 
pin 2 to 4.
•  check wiring and connection from E4 plug to HSI receiving plug.
•  replace HSI Assembly.
Continuity is present
Resistance should be between 11 and 20 Ohms at a temperature of 77°F.
Voltage is not present between E4, Pin 2 to ground
Replace ignition board.
Voltage is present
Continue
Voltage is not present between E4, Pin 4 to 
ground
•  check wiring and plug connections to hot surface igniter (HSI).  
•  replace HSI if needed.
Voltage is present
Note ignition board flash code LED.  Hot surface igniter (HSI) should work.