4
 
Assemble the instantaneous water heater as shown in 
the illustrations. Observe the information in the text.
 
S a f e t y   i n f o r m a t i o n
 
 
The instantaneous water heater must only be 
connected and started up by an authorised technician.
 
 
The statutory regulations of the respective country, as well 
as those of the local electricity and water suppliers must 
be adhered to.
 
 
The instantaneous water heater is an appliance of protec-
tion class 
 
I
 
 and 
 
must
 
 be connected to the protective earth 
conductor.
 
 
The unit have to be connected durably to the mains 
electricity supply via an all pole disconnecting device with 
contact gap must be at least 3 mm.
 
 
The instantaneous water heater is suitable for enclosed 
(pressurised) operation only.
 
 
The tap fittings must be permitted for operation with 
enclosed (pressurised) instantaneous water heaters.
 
 
The instantaneous water heater must only be connected 
to a cold-water pipe.
 
 
The instantaneous water heater is suitable for connection 
to DVGW-tested plastic pipes.
 
 
The instantaneous water heater must only be installed 
in a frost-free room.
 
 
Prior to installation, the electric connecting cable 
must be disconnected from the mains voltage and 
the water supply cut off!
 
 
Only connect the electric supply after the water 
supply.
 
 
When making holes in the rear panel, only make the 
number of holes required for installation. If the appliance 
is reinstalled, any holes that are not used must be made 
watertight.
 
 
Live components must not be touched subsequent to 
installation.
 
A s s e m b l y
Unpacking/removing the 
housing cover
 
 
Unpack the appliance and check for transportation 
damage.
 
 
Dispose of the packaging and, where applicable, the old 
appliance, in an environmentally conscious manner.
 
Preparation for assembly
Wall-mounted assembly
 
 
The instantaneous water heater must be fitted securely to 
the wall. If required, secure the appliance using the lower 
adjusting screws.
 
 
The distance from the wall is variable. This allows you to 
compensate for any unevenness in the wall surface.
 
 
The sleeve in the rear panel must fit tightly round the con-
nection cable. If the sleeve is damaged during installation, 
the holes must be sealed water-tight.
 
Water supply
 
 
The flow-through heater must be vented.  Open the 
warm water tap completely and allow to flow through 
for one minute.
 
Electric supply
 
 
The mains connection can either be mounted above or 
below. At least 40 mm of the connecting cord’s insulating 
jacket must be clamped inside the appliance.
 
Startup
 
 
For low water line pressure, remove the flow limiter (see 
Supplementary Information A).
 
 
Instruct the user with regard to the operation of the 
instantaneous water heater.
 
 
Separate the required language version from the rest of 
the operating instructions. This can be kept in the swing-
out control panel of the instantaneous water heater.
 
A d d i t i o n a l   i n f o r m a t i o n
 
If the flow-through heater does not achieve adequate 
flow as a result of water line pressure that is too low 
in your house installation, remove the flow limiter.
Priority circuit for the combination with electro-
storage heating units:
For operation with the priority circuit, a special load 
reducing relay (special accessory) is required. Other 
already existing load reducing relays with the 
exception of electronic load reducing relays could 
cause malfunctions.
Status Indicator in the Heater
I.
 
LED
Heater Status
 
Off
Off
On
Ready
Slow blinking (1/s)
Heating
II.
III.
IV.
V.
VI.
A
B
C
 
GB