Desa CGN10T 사용자 설명서

다운로드
페이지 32
25
102921
TECHNICAL
SERVICE
You may have further questions about installation, operation, or troubleshooting.
If so, contact DESA International’s Technical Service Department at 1-800-323-
5190.
SPECIFICATIONS
When gas pressure is too low
• pilot will not stay lit
• burner will have delayed ignition
• heater will not produce specified heat
When gas quality is bad
• pilot will not stay lit
• burner will produce flames and soot
• heater will backfire when lit
You may feel your gas pressure is too low or gas quality is bad. If so, contact your
local natural gas supplier.
SERVICE
HINTS
CGN10T
Btu (Variable)
5,000/10,000
Type Gas
Natural Only
Ignition
Piezo
Pressure Regulator Setting
3" W.C.
Inlet Gas Pressure (inches of water)
Maximum
10.5"
Minimum
4"
Dimensions, Inches (H x W x D)
Heater (Including knobs and grill)
21 1/2 x 13 1/2 x 7
Carton
25 1/4 x 16 3/4 x 7 1/2
Weight (pounds)
Shipping
19